User guide

250 DSView Installer/User Guide
option is not selected, the service will be added to the DSView software system as a
Windows NT Domain service.
e. Type the case-insensitive names of any DSView 2.x software database nodes that you do
not wish to import, separated by commas (,), in the Node Names to Ignore field. Any
children within the parent nodes listed in the field are also ignored (that is, not imported).
You may import a node containing a comma on its name by enclosing the node name
within quotation marks. For example, to import a node named node, two (containing a
comma) and a node named nodeone, type ”node,two”,nodeone in the Node Names to
Ignore field.
f. Click Next.
3. The Import in Progress window will open, updating to show the current step being performed,
as the DSView 2.x software database is importing. The Completed Successful window will
open when the import has completed and will contain a summary of the import, including the
following information:
Number of authentication services added
Number of users added
Number of user groups added
Number of units added
Number of unit groups added
4. Click Finish. The Units Tools window will open.
After running the Import DSView 2.x Database tool
The Migration Status field is enabled and displays in Unit Views windows. Units requiring
migration will contain Migration Needed in the Migration Status field.
Although the DS1800 digital switches, CPS appliances and DSR switches have been imported from
the DSView 2.x software database into the DSView software system, they are not yet compatible
with the DSView management software. To complete the configuration and update the firmware on
each type of DS1800 digital switch, CPS appliance and DSR switch, you must use the Migrate
Units task. See Task: Migrating DSView 2.x units to DSView software compatible units on
page 264 for more information.
Using the Managed Appliance Tools
The DSView management software contains tools that allow you to perform the following actions
on a DS1800 digital switch, DSI5100, CPS or CCM appliance or DSR switch:
Reboot
Upgrade the firmware
Resynchronize the managed appliance so that it reflects the current DSView software
system configuration