User guide
216 DSView Installer/User Guide
To build a login script and enable/disable automatic login:
1. Select Options - Session Properties from the menu bar.
-or-
Click the Session Settings icon in the toolbar.
The Session Properties dialog box will appear.
2. Click the Login Scripts tab.
3. Enable or disable the Automate login checkbox. The default value is disabled.
4. In the Initial Character list, select one option: CR (carriage return), CR+LF (carriage return and
linefeed), ESC (Escape), CTRL+P (Control+P sequence, 0X10 in hex) or None (no initial
transmission character).
5. In the Expect box, type the 1-32 alphanumeric character string that you expect from the device.
Spaces are allowed.
6. In the Send box, type the
0-32 alphanumeric character string that you wish to send in response
to the Expect string. Spaces are allowed, and a blank field is valid. A CR or CR+LF is
appended to the string, based on the New Line Mode - Outbound setting.
7. Repeat the Expect and Send entries as needed, to a maximum of four each.
Reviewing Session Data
During a Telnet Viewer session, you may review the accumulated screen contents by using the
scroll bar or the
Arrow keys. To return to the current session location, press Enter. The size of the
buffer containing session data that can be reviewed is configurable.
You may optionally choose to change the color of the text and/or the background when you are
reviewing session data. When you return to the current session location, the colors will return to
those specified in the Telnet Viewer’s configuration (see Customizing the Telnet Viewer on
page 211).
While you are reviewing collected data, new incoming data is buffered, but it will not be displayed
until you return to the current session location. You may not enter outgoing data.
To change the maximum number of lines in the session buffer:
1. Select Options - Session Properties from the menu bar.
-or-
Click the Session Settings icon in the toolbar.
The Session Properties dialog box will appear.
2. Click the Terminal tab.
3. In the History Buffer Size box, type a value from 1-1000. The default value is 256.