User guide

Chapter 4: Managing Units 133
devices using DSRIQ modules. The DSRIQ with an EID of 520255-044F6F is connected to target
device td-john, while 520255-03F757 is connected to td-mary and 520255-016BE0 is connected
to td-tim.
dsr-1021-huntsville(3)
520255-044F6Ftd-john
dsr-1021-huntsville(4)
520255-03F757td-mary
dsr-1021-huntsville(8)
520255-016BE0td-tim
Example: Cascade switch connection
In the following example, an AutoView 200 1 x 8 switch is connected to port one of a DSR1021
switch named dsr-1021-huntsville, using a DSRIQ module with an EID of 520255-023FB7. Each
port of the AutoView 200 switch is connected to a different target device (520255-023FB701
through 520255-023FB708).
dsr-1021-huntsville(1)
520255-023FB7switch one (1)520255-023FB701
dsr-1021-huntsville(1)
520255-023FB7switch one (2)520255-023FB702
dsr-1021-huntsville(1)
520255-023FB7switch one (3)520255-023FB703
dsr-1021-huntsville(1)
520255-023FB7switch one (4)520255-023FB704
dsr-1021-huntsville(1)
520255-023FB7switch one (5)520255-023FB705
dsr-1021-huntsville(1)
520255-023FB7switch one (6)520255-023FB706
dsr-1021-huntsville(1)
520255-023FB7switch one (7)520255-023FB707
dsr-1021-huntsville(1)
520255-023FB7switch one (8)520255-023FB708
Example: SPC device connection
In the following example, an SPC device is connected to the SPC port of a DSR1021 switch named
dsr-1021-huntsville. SPC device outlet A1 is connected to target device 02-17-F2 SPC A1.
dsr-1021-huntsville(SPC)
02-17-F2 SPC (A1)02-17-F2 SPC A1
Customizing the Target Device Connections window
By default, the following field displays in the Target Device Connections window and may be
removed using the Customize link:
Type - Displays the type of connection:
KVM - Connection to a port of a DS1800 digital switch or DSR switch using a
DSRIQ module.
Virtual Media - Virtual media connection.
Serial - Serial port connection to a CPS or CCM appliance.
Power - A connection to an SPC device outlet.
IPMI - A connection to a DSI5100 appliance.