User guide
16.....Avocent® ACS6000 Advanced Console Server
--:- eth0 cli-> list_configuration
echo off
cd /network/devices/eth0
batch_mode
set status=enabled
set ipv4_method=dhcp
#set ipv4_method=static #ipv4_address=192.168.160.10 #ipv4_mask=255.255.255.0
#set ipv4_method=ipv4_address_unconfigured
#set ipv6_method=stateless
#set ipv6_method=dhcpv6
#set ipv6_method=static #ipv6_address= #ipv6_prefix_length=
set ipv6_method=ipv6_address_unconfigured
set mode=auto
submit
echo on
commit
--:- eth0 cli->
NOTE: Check the configuration of the program used to open a session against the appliance (SSH/Telnet,
TeraTerm / HypertTerminal for console, and so on) to avoid the inclusion of a line feed character in lines that
exceed terminal width, because this will affect the past operation.
cycle, on, off, lock and unlock
Control power on outlets on a PDU that is either connected to a serial port or to the AUX/Modem
port when the port is enabled and configured with the Power Profile.
NOTE: Lock and unlock commands are only supported on Cyclades and Avocent PDUs.
To power control (on, off, cycle) all outlets of PDUs or outlets merged to a target (serial
port configured as CAS profile with merged outlets):
1. Go to the access level.
--:- / cli-> cd/access
2. Launch the power command with the argument being the target name or PDU ID.
--:- access cli-> [cycle|on|off][<PDU_ID>]|<target name>]
To power control (on, off, cycle) outlets of one specific PDU:
1. Go to the PDU level under access.