User guide
86 Cyclades® CS Console Server Installation, Administration and User Guide
7. Enter the IP address of the SMTP Server.
8. Enter a message in the Body text area.
9. Click OK.
10. Click apply changes.
Serial ports alarm notification
You can configure the notification entry form to monitor the DCD signal so that the system will
generate an alarm in any of the following events.
• A serial console cable is removed from the console server
• A device/server attached to the console is powered down
The configuration also enables you to detect if a modem is in use and is still powered on and active.
To configure a trigger for serial port alarm notification:
1. Go to Administration - Notifications in Expert mode.
2. Enable the checkbox for Notification Alarm for Data Buffering.
3. Select Email, Pager or SNMP Trap from the pull-down menu.
4. Click the Add button.
5. Enter
Port in the Alarm Trigger field.
6. Configure the parameters selected in step 3. See Notifications on page 84.
7. Click OK.
8. Click apply changes.