User guide
Chapter 4: Configuring the Cyclades CS Console Server in Wizard Mode 19
Step 2: Port Profile
Selecting Step 2: Port Profile displays a form for configuring the Console Access Profile (CAS).
The protocol used to access the serial ports can be configured in this form.
Figure 4.3: Wizard - Step 2: Port Profile
In Wizard mode, the system assumes that all devices will be connected to the serial ports with the
same parameter values. If you need to assign different parameters to the serial ports that each server
or device is connected to, use the Expert mode, Ports - Physical Ports to assign individual
port parameters.
Table 4.1: Port Profile Setup Options
Parameter Options Description
Connection Protocol Console (Telnet) [Default]
Console (ssh)
Console (Telnetssh)
Console (Raw)
Sets the protocol to be used to connect to devices
that are connected to serial ports.
Console (ssh) encrypts data and
authentication information.
Console (Telnetssh) allows users to connect using
either protocol.
Console (Raw) is for unnegotiated plain
socket connections.
Use Expert mode if you wish to specify any of
several other connection protocols that are listed
under Ports-Physical Ports-Modify-General.
Flow Control None [Default]
Hardware
Software
Must match the flow control method of the devices
connected to all serial ports.
Parity None [Default]
Odd
Even
Must match the parity used by the devices
connected to all serial ports.