User guide

Parameter Description
Log-in/out Message
Includes special notification for logins and logouts in data buffering.
Default: Disabled.
Serial Session Logging
Enabled - stores data at all times. Disabled - stores data when a CAS
session is not opened. Default: Enabled.
Alerts
Status
A special event notification will be generated when input data matches
one of the alert strings. Default: Disabled.
Alert Strings Strings used to generate event notifications. Default: Empty.
To configure the Dial-in Profile for a serial port with a connected modem:
1. Select Ports - Serial Ports.
2. Click the checkbox for a serial port with a connected modem.
3. Click the Set Dial button and use the drop-down menus to configure the dial-in settings.
4. Configure the PPP parameters (address, authentication and so on) and click Save.
Parameter Description
Status Enables or disables the port. Default: Disabled.
Speed
The speed that will be used by mgetty to configure the serial device.
Default: 38400 bps.
Init Chat Chat for modem initialization. Default: "" \d\d\d+++\d\d\dATZ OK.
PPP Address
Configures the local and the remote IP address for the the PPP link. If
Accept Configuration from Remote Peer is selected, the remote peer
should send both IP addresses (local and remote) during negotiation.
Default: No Address.
Local IPv4/IPv6
Address
Configures the local IPv4/IPv6 address for this PPP connection.
Remote IPv4/IPv6
Address
Configures the remote IPv4/IPv6 address for this PPP connection.
Table 3.6: Dial-in Parameters
Chapter 3: Accessing the Console Server via the Web Manager 41