User guide
Parameter Description
Enable Auto Answer
When the input data matches one input string configured in Auto
Answer, the output string will be transmitted to the serial port. Default:
Disabled.
DTR Mode
DTR Mode can be set to the following: Always On. Normal - the DTR
status will depend on the existence of a CAS session. Off Interval -
when the a CAS session is closed, the DTR will stay down during this
interval. Default: Normal.
DTR Off Interval
Interval in seconds used by DTR Mode Off Interval in milliseconds.
Default: 100.
Line Feed Suppression
Enables the suppression of the LF character after the CR character.
Default: Disabled.
Null After CR Sup-
pression
Enables the suppression of the NULL character after the CR char-
acter. Default: Disabled.
Transmission Interval
The interval the port waits to send data to a remote client in mil-
liseconds. Default: 20.
Break Sequence
Sequence used to send a break signal to the serial port. Not available
for Raw. Default: ~break.
Break Interval
Interval for the break signal in milliseconds. Not available for Raw.
Default: 500.
Log In/Out Multi Ses-
sion Notification
Enables the notification to multi-session users when a new user logs in
or a user logs out. Not available for Raw. Default: Disabled.
Informational Message
Notification
Displays an information message when a target session is opened. Not
available for Raw. Default: Enabled.
Data Buffering
Status Enables or disables data buffering. Default: Disabled.
Type
Displays the type of data buffering: Local - stores the data buffering file
in the local file system. NFS - stores the data buffering file in the NFS
server. Syslog - sends the data to the syslog server. DSView - sends
the data to the DSView 3 software. Default: Local.
Time Stamp
When enabled, adds the time stamp to the data buffering line for a
Local or NFS database. Default: Disabled.
40 Cyclades™ ACS 6000 Advanced Console Server Installation/Administration/User Guide