Service manual

122 Cyclades ACS 5000 Advanced Console Server Command Reference Guide
Expressions
To Configure IPMI:
1. Enter the following command to enable IPMI or edit an existing configuration.
cli> config ipmi [add |edit|delete]
2. Configure serial ports for power management and IPMI protocol. Refer to Table A.10 for
configuration parameters.
cli> config physicalports <'all' or range/list[1-xx] powermanagement
[disableIPMI | enableIPMI] <key <^(character)>> <server <name>>
Table A.9: IPMI Commands
Expression Description
raw Send a RAW IPMI request and print response
i2c Send an I2C Master Write-Read command and print response
lan Configure LAN Channels
chassis Get chassis status and set power state
event Send pre-defined events to MC
mc Management Controller status and global enables
sdr Print Sensor Data Repository entries and readings
sensor Print detailed sensor information
fru Print built-in FRU and scan SDR for FRU locators
sel Print System Event Log (SEL)
pef Configure Platform Event Filtering (PEF)
sol Configure IPMIv2.0 Serial-over-LAN
isol Configure IPMIv1.5 Serial-over-LAN
user Configure Management Controller users
channel Configure Management Controller channels
session Print session information
sunoem OEM Commands for Sun servers
exec Run list of commands from file
set Set runtime variable for shell and exec