AMX™ Switch Series For Technical Support: Installer/User Guide Guide d’installation et d’utilisation Email: support@avocent.com www.avocent.com Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA Tel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. POWER ON This symbol indicates the principal on/off switch is in the on position.
AMX Switch Series Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AMX, AMWorks, OSCAR, AutoView, DSR, OutLook, SwitchView and XP are trademarks or registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. © 2004 Avocent Corporation. All rights reserved.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
iii TABL E OF CONTEN TS Table of Contents List of Figures .................................................................................................................. v List of Tables .................................................................................................................. vii Chapter 1: Product Overview.......................................................................................... 1 Features and Benefits ...........................................................
iv AMX Switch Series Installer/User Guide TABL E OF CONTEN TS AMIQ module............................................................................................................................ 20 AMIQ-SRL module.................................................................................................................... 20 OSCAR Interface Overview ............................................................................................................. 20 Target..............................
v L IS T O F F IG URE S List of Figures Figure 1.1: AMX5000/5010 Switch Model Comparison ................................................................... 4 Figure 1.2: Typical AMX Switching System Configuration .............................................................. 5 Figure 2.1: Basic AMX Switching System Configuration................................................................ 10 Figure 2.2: AMX5000 Switch ....................................................................................
vi AMX Switch Series Installer/User Guide Figure 4.11: OSCAR Interface Inactivity ........................................................................................ 41 Figure 4.12: OSCAR Interface Command Line ..............................................................................
vii L I S T OF T A B L ES List of Tables Table 1.1: Target KVM Switches in AMX Cascaded Switching System ............................................ 3 Table 3.1: User Station Rear Panel LEDs....................................................................................... 20 Table 3.2: OSCAR Interface Navigation Buttons ............................................................................ 21 Table 3.3: PS/2 Keyboard to Sun Computer .............................................................
viii AMX Switch Series Installer/User Guide Table D.7: IBM C2T ........................................................................................................................ 62 Table D.8: KVM Switch ...................................................................................................................
1 CHA PTER 1 Product Overview Features and Benefits The Avocent AMX™ Switch Series allows multiple users within the switching system to access and operate PC, USB or Sun servers and serial devices at the same time. A basic AMX switching system configuration connects users and servers to one or more AMX KVM (keyboard, video and mouse) switches, as well as other KVM switches (Avocent or non-Avocent branded).
2 AMX Switch Series Installer/User Guide with four users accessing four different servers is a 4 x 4 matrix. Eight users accessing 10 different servers would be an 8 x 10 matrix. Sharing If two or more users need access to the same server or serial device, they can share access through the AMX Series switch. Sharing enables multiple users to switch to the same server at the same time. All connected users can see the server’s video, but only one user can enter data at any given moment.
Chapter 1: Product Overview 3 See Chapter 4 in this user guide or the AMWorks software online Help program on your installation CD for instructions on managing devices in your AMX switching system. Table 1.
4 AMX Switch Series Installer/User Guide Component Overview An AMX switching system may consist of four main components: • One or more AMX switches and other KVM switches • Avocent matrix user station • Avocent matrix intelligent module [AMIQ module, AMIQ-SRL (serial) module] • Unshielded Twisted Pairs (UTP) cables The quantity and type of components you receive depend on the specific configuration you order. The AMX switch The AMX switch provides the framework for the AMX switching system.
Chapter 1: Product Overview 5 The AMX5100 user station provides one RJ-45 port, enabling the connection of one AMX switch. The AMX5110 and AMX5120 user stations provide two RJ-45 ports, enabling the connection of one AMX switch and one AMIQ module or two AMIQ modules. Connections to two separate switches are not supported on the AMX5110 or the AMX5120 user station. The AMX5120 user station provides skew compensation that maximizes video quality.
6 AMX Switch Series Installer/User Guide server within the system. The connection between the AMX switching system and these modules is through industry standard UTP cabling. UTP cables The AMX switching system uses video technologies that compensate for the losses that occur in all UTP cables. These technologies make the AMX switch compatible with most UTP cable types and support AMX switch use in environments where there are combinations of UTP cable types and patch panels.
Chapter 1: Product Overview 7 • Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. • Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Consider equipment nameplate ratings for maximum current.
8 AMX Switch Series Installer/User Guide
9 CHA PTER 2 Installation The AMX switching system uses standard UTP cables to transmit keyboard, video and mouse information between users and attached servers. Getting Started Before installing your AMX switching system, refer to the following lists to ensure that you have all the items that shipped with the AMX switching system as well as other items necessary for proper installation.
10 AMX Switch Series Installer/User Guide Needed for installation You will need the following components to install the AMX switch: • UTP cables for each server and user station you plan to attach to the AMX switching system • One AMX5100, AMX5110 or AMX5120 user station per user • One AMIQ module per server or one AMIQ-SRL module per serial device Optionally you may need: • AMWorks software available on the included CD and through download from Avocent Installing an AMX Switching System Figure 2.
Chapter 2: Installation 11 NOTE: To reduce the risk of electric shock or damage to your equipment - Do not disable the power cord grounding plug. The grounding plug is an important safety feature. - Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times. - Disconnect the power from the unit by unplugging the power cord from either the electrical outlet or the unit. Installing an AMX Switch The AMX switch is the central hub of your AMX switching system.
12 AMX Switch Series Installer/User Guide Figure 2.4: AMX5000 Switch Rack Mounting Diagram Figure 2.5: AMX5010 Switch Rack Mounting Diagram To install the rack mounting bracket: 1. Remove the two side screws closest to the front from each side of your AMX switch. 2. Line up the holes in the brackets with the holes on the sides of the AMX switch. 3.
Chapter 2: Installation 13 3. When the power is switched on, the Power indicator on the front of the unit will remain orange for approximately 30 seconds while performing a self-test and then change to green. This indicates a healthy condition. 4. Next, follow these instructions to set up the Terminal Applications menu. Refer to Chapter 5 for more details. a. You will be prompted to enter a username. The first time you access the switch, enter the username admin and press Enter.
14 AMX Switch Series Installer/User Guide Network Port User Ports Server Ports Figure 2.6: AMX5000 Switch Rear Panel Terminal Port Network Port User Ports Server Ports Figure 2.7: AMX5010 Switch Rear Panel To connect servers to the AMX switching system: 1. Locate an AMIQ module appropriate to the server you wish to attach. 2. Plug the AMIQ connectors into the appropriate ports on the back of the selected server. 3. Connect one end of a UTP cable into the RJ-45 port on your AMIQ module.
Chapter 2: Installation 15 3. Attach one end of the CAT 5 cable to the RJ-45 connector on the AMIQ-SRL module. Connect the other end of the CAT 5 cable to the desired computer port on the back of your AMX switch. 4. Connect the power supply to the power connector on your AMIQ-SRL module. The cable expander can be used to power up to four AMIQ-SRL modules from a single power supply. 5. Connect the AMIQ-SRL module power supply to an appropriate AC wall outlet to power up your serial device.
16 AMX Switch Series Installer/User Guide 3. Connect one end of a UTP cable into the RJ-45 port on the user station. Route the cable to your AMX5000 switch or AMX5010 switch and connect the other end to one of the available RJ-45 user ports. 4. Either RJ-45 port on the AMX5110 or AMX5120 user station can be used to connect to the AMX switch. Connections to two separate AMX switches are not supported on the AMX5110 and AMX5120 user stations. 5. Locate the power cord that shipped with the user station.
Chapter 2: Installation 17 Local Users AMX5010 Switch AMX5110 User Station AMX5000 Switch AMX5000 Switch Servers Servers Servers AMX5000 Switch AMX5000 Switch Servers AMX5000 Switch AMX5000 Switch Servers Servers Figure 2.10: Cascaded AMX Switching System To install a cascaded AMX switching system: 1. Position the AMX switches that will be connected and select a switch to be the primary hub. 2. Connect one end of a UTP cable into a server port on the primary hub.
18 AMX Switch Series Installer/User Guide NOTE: The AMX switch can be used with non-Avocent KVM switches. Switching to a port with an attached nonAvocent KVM switch requires the use of the OSD of the non-Avocent unit to continue the switch. Configuring the AMX switch database Once all users, servers and switches have been attached and connected to the LAN, configure the AMX switch database of servers and users.
19 CHA PTER 3 Basic Operations Power Up and LEDs AMX5000 switch or AMX5010 switch There are three groups of LEDs on the front panel of your AMX5000 switch or AMX5010 switch. Each green LED in the left group corresponds to a server port. Each LED illuminates when the system or cascaded AMX switch is attached and powered up. Figure 3.1: AMX5000 Switch The green and amber LEDs in the center group indicate the status of your LAN connection.
20 AMX Switch Series Installer/User Guide Figure 3.2: AMX5110 User Station The rear panel of the AMX5110 user station and the AMX5120 user station provides two LEDs, one green and one yellow, mounted on each UTP port connector. The green LEDs indicate the connection status of each port. The yellow LEDs indicate the activity status of each port. The rear panel UTP port LEDs are described in the following table. Table 3.
Chapter 3: Basic Operations 21 The OSCAR graphical interface consists of five main tabs: Target, User, Console, Admin and ?. The arrow buttons provide easy navigation through the OSCAR interface subscreens, as described in the following table. Table 3.
22 AMX Switch Series Installer/User Guide Maintain Use Maintain mode when you wish to remain connected to a server while rebooting. Once selected in Maintain mode, the server will not lose contact with the switch when power to the server is cycled. NOTE: Servers in Maintain mode cannot be shared. User The User tab enables you to control your system at the local port. The User tab screens enable you to change your password and the scan dwell time.
Chapter 3: Basic Operations 23 Figure 3.3: OSCAR Interface User Tab 3. Enter your current password. 4. Enter your new password and verify it in the fields provided. Your password must be at least six characters in length. Click Apply. NOTE: Should you lose your password, please contact Avocent Technical Support for assistance. 5. (Optional) Change the scan dwell time by typing a number between 3 and 99. Click Apply. 6. Click Cancel to exit the OSCAR interface.
24 AMX Switch Series Installer/User Guide Figure 3.4: OSCAR Interface Target Flag 4. Click the Name button to display the connected server name on the target flag. - or Click the UID button to display the connected server UID on the target flag. 5. Click the double arrow button to display the Text drop-down list. Select the text color for the target flag. 6. Click the double arrow button to display the Background drop-down list. Select the background color for the target flag. 7.
Chapter 3: Basic Operations 25 NOTE: Pressing the Esc key enables you to return to the Target Flag screen without saving the new position. 13. Click Apply to apply and save all changes to the target flag. 14. Click Cancel to exit the Target Flag screen. To set or change a server hotkey: 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. When the OSCAR interface dialog box appears, click the User tab. The User screen displays. 3.
26 AMX Switch Series Installer/User Guide Figure 3.7: OSCAR Interface Change Hotkey 7. Click the down arrow button and select the desired hotkey from the drop-down list. Click OK. NOTE: If the selected hotkey is already assigned to a different server, you can re-assign the selected hotkey or return to the Change Hotkey screen to select another hotkey. NOTE: The Clear button enables you to clear the selected hotkey assignment.
Chapter 3: Basic Operations 27 Shift+Shift (L-R) Shift+Shift (L) Shift+Shift (R) Scroll Lock+Scroll Lock For more information, see Console Maintenance in Chapter 4. Admin The Admin tab displays options for editing user and server information. Only users with Administrator rights can access editing screens to configure user and server information for servers connected to the AMX switching system. Any user can access editing screens for the local computer.
28 AMX Switch Series Installer/User Guide 4. To disconnect from a selected server, activate the OSCAR interface and click the Disconnect button or switch to another server. To scan an AMX switching system: 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Select the Target tab and click the Scan radio button. Figure 3.8: OSCAR Interface Target Tab Press and hold the Ctrl key while you individually select the servers that you would like to scan.
Chapter 3: Basic Operations 29 Keyboard Translation The AMX user station allows you to use PS/2 and Sun keyboards to operate any type of attached computer. However, when crossing platforms, certain keys will need to be remapped in order to provide all of the functions available on the keyboard native to that platform. For example, if you access a Sun workstation with a PS/2 keyboard, you will notice that the PS/2 keyboard does not have the Stop and Again keys that are on a true Sun keyboard.
30 AMX Switch Series Installer/User Guide The following table shows the Power/Sleep key on USB computers for Sun and PS/2 keyboards. Sun keyboards have a Power key used to power the workstation. PS/2 keyboards may have a Sleep key to place the computer in a stand-by or power saving mode. Table 3.
31 CHA PTER 4 Advanced Operations User Maintenance The AMX switching system can be configured to support up to 128 users. Each user is identified by a unique name and password and can be assigned full, view only or no rights to servers attached to the AMX switch. These actions, as well as deleting and editing users once they are configured, are performed through the Admin menu and require that the user be logged in under the Admin user. You also can perform user maintenance through the AMWorks software.
32 AMX Switch Series Installer/User Guide Figure 4.2: OSCAR Interface Add User 5. Enter the name of the user in the Username field. 6. Enter the user’s password and confirm it in the provided fields. 7. Click OK. To edit a user: 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Click the Admin tab. 3. Click the down arrow to display the User Admin screen. 4. Select the user you wish to edit. Click the Edit User button. The Edit User screen displays. Figure 4.
Chapter 4: Advanced Operations 6. Click OK. 7. Click Cancel to return to the User Admin screen. To force user login: 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Click the Admin tab. 3. Click the down arrow to display the User Admin screen. 4. Select Admin from the list and click the Edit user button. The Edit User screen displays. 5. Click the Force User Login checkbox to automatically force all users to log in. 6. Click OK to apply and save changes. 7.
34 AMX Switch Series Installer/User Guide Figure 4.4: OSCAR Interface User Rights 6. To change a user’s access rights to a single server, click the target from the list of available servers. Select the appropriate access level: none, view or full. - or To change a user’s access rights to multiple servers, press the Ctrl key and select the targets from the list of available servers that you wish to be controlled externally. Select the appropriate access level: none, view or full.
Chapter 4: Advanced Operations 35 Figure 4.5: OSCAR Interface Device Admin To edit a device (normal configuration): 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Click the Admin tab. The Device Admin screen displays. NOTE: The devices displayed on the Device Admin screen depend on the assigned user rights. It is only possible to edit devices that are attached to the AMX switching system and powered. Only users logged in as the system administrator may edit all devices except Matrix System. 3.
36 AMX Switch Series Installer/User Guide The UID and Type fields are not editable. The Type field displays the type of device being edited, including one of the following: • PS/2 Single-Port • SUN Single-Port • USB Single-Port • Serial Single-Port • MDM Server 5. Type a new name (1-15 characters) for the device in the Name field. 6. If the device is an AMIQ-USB or an AMIQ-vSN, select a keyboard country layout, shown in Table 4.1, from the Layout drop-down list.
Chapter 4: Advanced Operations 37 NOTE: The devices displayed on the Device Admin screen depend on the assigned user rights. It is only possible to edit devices that are attached to the AMX switching system and powered. Only users logged in as the system administrator may edit all devices except Matrix System. 3. From the drop-down list, select the device you wish to edit. 4. Click the Edit Device button. The Edit Device screen displays. 5.
38 AMX Switch Series Installer/User Guide To view AMIQ module information: 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Click the Admin tab. The Device Admin screen displays. 3. Select the AMIQ module for which you wish to view version, configuration and connection information. 4. Click the Edit device button. The Edit Device screen displays. 5. Click the Info button. The Information screen displays. Figure 4.8: OSCAR Interface Information: AMIQ Module 6.
Chapter 4: Advanced Operations 2. 39 Click the Console tab. The Status screen displays the connection status on the AMX user station. Figure 4.9: OSCAR Interface Status 3. Click the double arrow navigation button to display the Configure screen. Figure 4.10: OSCAR Interface Configure 4. The Keyboard Layout field displays the current keyboard layout. Click the double arrow button to scroll through and select the desired option.
40 AMX Switch Series Installer/User Guide 5. If the Type field is activated, click the double arrow button and select Standard or Pinnacle FAK. When you make a change in the Type field, the change will be highlighted in blue text. NOTE: Standard refers to any keyboard. If your AMX user station is connected to a Pinnacle FAK, you must select Pinnacle FAK in the Type field to enable support for this keyboard. 6. Click Apply to apply and save changes. 7. (Optional) Change the OSD hotkey sequence.
Chapter 4: Advanced Operations To enable and set lockdown: NOTE: Before the lockdown feature can be enabled, the Force User Login option must be enabled and the Admin user must be logged on. See User Maintenance in Chapter 3 for more information. 1. Press Ctrl+Ctrl to launch the OSCAR interface. 2. Click the Console tab. 3. Click the down arrow to display the Configure screen. 4. Under Lockdown, click User to prevent changes to the User tab.
42 AMX Switch Series Installer/User Guide Forcing an External Switch The AMX system enables an external network source to control switching within the AMX switch using the SNMP. The access rights that apply to the SNMP control are assigned to a user named “snmpUser.” After adding and setting access rights for the snmpUser, you are ready to force a switch to any of the servers to which the snmpUser has access. For instructions on adding an SNMP user, see To add a user in this chapter.
Chapter 4: Advanced Operations 43 To force a user to make or break a connection: NOTE: The following rules apply for optimum operation of the force connection feature: - Both the user entering the command and the user at the target user station must have rights to the server. - All force connections are done in Shared mode. - All user stations and AMIQ modules must have unique names.
44 AMX Switch Series Installer/User Guide
45 CHA PTER 5 Terminal Operations Accessing the Terminal Menu Each AMX5000 switch or AMX5010 switch can be configured at the unit level through the Terminal port. All terminal commands are accessed through a terminal or PC running terminal emulation software.
46 AMX Switch Series Installer/User Guide All AMX5000 or AMX5010 switches that are part of the same AMX configuration must have the same configuration ID. Set the IDs of all AMX switching system configurations that will be connected to the same subnet as shown in the following table. Continue this numbering system for all other AMX switching system configurations connected to the same subnet. Table 5.
Chapter 5: Terminal Operations 47 To configure SNMP processing: 1. On the Serial Console Main Menu, press 4 to select SNMP Configuration. The SNMP Configuration Menu displays. 2. Press 1 and Enter to toggle the SNMP mode from Disabled to Enabled. 3. Press 2 and Enter to specify the community to which traps will be read. Enter the community name and Enter. 4. Press 3 and Enter to specify the community name to which traps will be written. Enter the community name and press Enter. 5.
48 AMX Switch Series Installer/User Guide Load the AMX-MIB file into your SNMP browser to start monitoring and managing AMX switchspecific objects. Once you have enabled the sending of traps on the AMX switch, these traps can be interpreted by the SNMP trap listener by using the trap-specific MIB files. The following table describes the MIB files required for the SNMP processing. Table 5.
49 A P P EN D IC ES Appendices Appendix A: Technical Specifications Table A.1: AMX5000 Switch Specifications Server Ports Number 32 Connectors RJ-45 AMX switch interconnect User Ports 8 Number 1 Connectors RJ-45 AMX switch interconnect Network Connection Number 1 Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port Number 1 Type RS-232 serial Connector DB9 male Dimensions HxWxD 4.45 x 43.2 x 28.1 cm 1 U form factor (1.75 x 17 x 11) Weight 3.
50 AMX Switch Series Installer/User Guide Table A.2: AMX5010 Switch Specifications Server Ports Number 64 Connectors RJ-45 AMX switch interconnect User Ports Number 16 Connectors RJ-45 AMX switch interconnect Network Connection Number 1 Type Ethernet, 10BaseT, 100BaseT Connector RJ-45 Terminal Port Number 1 Type RS-232 serial Connector DB9 male Dimensions HxWxD 4.45 x 43.2 x 28.1 cm 2 U form factor 1 Weight 7.
Appendices 51 Table A.3: AMX User Station (AMX5100, AMX5110 or AMX5120 User Station) Product Specifications Server Ports Number AMX5100 user station: 1; AMX5110 and AMX5120 user station: 2 Connectors RJ-45 AMX switch interconnect User Ports Number PS/2: 1; Sun: 1; VGA video: 1 Type PS/2, Sun and VGA video Connectors 6-pin miniDIN, PS/2 keyboard and mouse; 8-pin miniDIN, Sun keyboard and mouse;15HDD female Dimensions HxWxD 4.45 x 27.9 x 29.2 cm 1U form factor 1.75 10.98 x 11.
52 AMX Switch Series Installer/User Guide Table A.
Appendices 53 Table A.5: AMIQ-SRL Module Product Specifications Server Ports Number 1 Type DCE Connectors 9-pin D-sub female User Ports Number 1 Connectors RJ-45 AMX switch interconnect Serial Ports Type DCE Emulation VT100 Baud Rate 115200, 57600, 38400, 19200, 9600, 2400, 1200, 300 bits per second Parity Even, Odd, None Flow Control None, CTS/RTS or XOn/XOff Dimensions HxWxD 2.0 x 4 x 21.5 (with serial connector) cm (.83 x 2.43 x 4.02 in) Weight 0.13 kg (.
54 AMX Switch Series Installer/User Guide Appendix B: Using AMIQ-SRL Modules The AMIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewed from the AMX switch local port. The actual serial data is not accessed, but is merely displayed. All serial data coming from the target device is displayed in a VT100 window, placed into a video buffer and sent to the AMX switch as though it came from a VGA server.
Appendices 55 • Received: This option enables you to specify how the module translates a received Enter character. Available options are (Enter) or (Enter - Linefeed). • Background: This option changes the screen’s background color. The currently-selected color displays in the option line as it is changed. Available colors are Black, Grey, Light Grey, White, Yellow, Green, Teal, Cyan, Blue, Dark Blue, Purple, Pink, Orange Red, Maroon and Brown. The default color is Black.
56 AMX Switch Series Installer/User Guide 2. Select a parameter to change. You can navigate the Configuration Screen using the Up Arrow and Down Arrow keys. 3. Modify the selected value using the Left Arrow and Right Arrow keys. 4. Repeat steps 2 and 3 to modify additional values. 5. Press Enter to save your changes and exit the Configuration Screen. - or Press Esc to exit the Configuration Screen without saving the changes.
Appendices 57 To use History mode: 1. Press Ctrl-F9. The mode will display as History. 2. Press each key to perform the action described in the following table.. Table B.1: History Mode Control Keys History Mode Action Home Move to the top of the buffer. End Move to the bottom of the buffer. Page Up Move up one buffer page. Page Down Move down one buffer page. Up Arrow Move up one buffer line. Down Arrow Move down one buffer line. CTRL-F Enters Configuration mode.
58 AMX Switch Series Installer/User Guide Table B.2: AMIQ-SRL Module Pinouts (Continued) DB9-F Host Signal Name/Description Signal Flow SRL Signal Name/Description 8 CTS - Clear to Send Out of SRL RTS - Request to Send 9 N/C - Not Connected N/A N/C - Not Connected Language support The AMIQ-SRL module is designed to operate correctly with all of the keyboard layouts that are selectable on the AMX5000 switch and the AMX5010 switch.
Appendices 59 Appendix C: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service: 1. Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined. 2. Check our web site at www.avocent.com/support to search the knowledge base or use the on-line service request. 3.
60 AMX Switch Series Installer/User Guide Appendix D: OSCAR Interface Edit Device Screen Settings Table D.1: AutoView KVM Switch Edit Device Screen Settings Target AutoView switch Ports 4, 8 Hotkey NumLock + “-”, NumLock + “+”, Ctrl + “~” Table D.2: AutoView 200, 400, 416 or 424 Switch Edit Device Screen Settings Target AutoView switch Ports AutoView 200, 400 switches: 4,8; AutoView 416 switch: 16 AutoView 424 switch: 24 Hotkeys NumLock + “-”, NumLock + “+”, Ctrl + “~” Table D.
Appendices Table D.4: AV2000R, AV1000R, AV2000 or DSR Switch Edit Device Screen Settings Target AV2000R, AV1000R, AV2000 or DSR switch Ports AV2000R, AV1000R, AV2000 switches:16 DSR switches: 8, 16 Hotkeys The Print Screen key is not operational for a server connection Unit Settings Required: Setting the display order of the server list to “Port” Recommended: Setting the OSD screen display time to 2 seconds Table D.
62 AMX Switch Series Installer/User Guide Table D.7: IBM C2T Edit Device Screen Settings Target IBM C2T Ports up to 32 Hotkey NumLock–NumLock Table D.
63 INDEX Index connecting serial devices 14 A connecting servers 14 add user 31 connecting users 15 Add User screen 32 FLASH upgrading 18 adjust keyboard layout 38 installing cascaded 16 ambient temperature 6 AMIQ AMX user station descriptions of 4 -vSN module 36 keyboard layouts 36, 40 -xSN module 36 LEDs 20 AMIQ module 5 specifications for 51 LEDs 20 specifications 52 AMX5000 switch rear panel 14 viewing information 38 specifications 49 AMIQ-SRL module 5 configuring 54 AMX5010 swit
64 AMX Series Installer/User Guide servers 14 users 15 Console Maintenance Configure screen 38 keyboard layouts 40 H History mode control keys 57 hotkey sequences 26 HyperTerminal 12 lockdown 41 I Status screen 39 inactivity time 41 Console tab 26 Information screen viewing AMIQ module 38 D Data Communication Equipment 5 viewing MDM server 37 installation DCE required components 10 See also Data Communication Equipment DDC See Digital Data Channel K Keyboard layouts DDC table 43 delete user
Index MDM AMIQ modules 34 MDM server 34, 36 viewing information 37 mechanical loading 7 Multiple Device Mode 2 65 R rack loading 11 rack mounting bracket installing 12 reduced air flow 6 reliable earthing 7 N NVision Router 2 RJ-45 5 S O online Help 3 OSCAR configure inactivity time 41 Console tab 26 delete user 33 Device Admin screen 35 device information 37 edit device 35 enable lockdown 41 graphical user interface 3, 20 set user rights 33 Target Flag 24 Target tab 21 safety 6 scan dwell time 22 S
66 AMX Series Installer/User Guide adding 42 accessing 45 specifications 49–53 activating security 46 switch AMX-MIB file 48 AMX5000 4 commands 45 AMX5010 4 managing AMX objects 47 cascaded 1, 3 Network Configuration 45 SNMP Configuration 46 T SNMP processing 47 tab System Management 45 ? 27 Console 26 U Target 21 Uninterruptible Power Supply (UPS) 6 User 22 User Admin screen 31 Target Flag configuring 23 user maintenance 31 User Rights screen 34 Target Flag screen 24 User tab 22
Index 67
68 AMX Series Installer/User Guide
INSTRUCTIONS Ce symbole est destiné à attirer votre attention sur la présence de consignes importantes liées au fonctionnement et à la maintenance (l’entretien) dans la documentation accompagnant le matériel. TENSION DANGEREUSE Ce symbole est destiné à vous avertir de la présence de « tensions dangereuses non isolées à l’intérieur de l’appareil, pouvant être suffisamment élevées pour constituer un risque de choc électrique pour les individus.
Commutateurs de la série AMX Guide d’installation et d’utilisation Avocent, le logo Avocent, The Power of Being There, AMX, AMWorks, OSCAR, AutoView, DSR, Outlook, SwitchView et XP sont des marques de commerce ou des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété exclusive de leurs détenteurs respectifs. © 2004 Avocent Corporation. Tous droits réservés.
Notification pour les États-Unis Avertissement : Les modifications apportées à ce produit sans l’accord exprès de la partie responsable de la conformité peuvent annuler l’autorisation dont vous bénéficiez pour utiliser cet équipement. Nota : L’équipement a été testé et déclaré conforme aux limites définies pour les appareils numériques de classe A, suivant l’article 15 du règlement de la FCC.
iii TABLE DES MATIÈRES Liste des figures .............................................................................................................. v Liste des tableaux ......................................................................................................... vii Chapitre 1 : Présentation du produit ............................................................................. 1 Caractéristiques et avantages .................................................................................
iv Guide d’installation et d’utilisation des commutateurs de la série AMX Module AMIQ .......................................................................................................................... 20 Module AMIQ-SRL .................................................................................................................. 20 Présentation de l’interface OSCAR ................................................................................................ 20 Onglet Target ................
v LISTE DES FIGURES List of Figures Figure 1.1 : Comparaison des modèles de commutateurs AMX5000 et AMX5010 .......................... 5 Figure 1.2 : Configuration typique du système de commutation AMX ............................................. 6 Figure 2.1 : Configuration de base du système de commutation AMX ........................................... 11 Figure 2.2 : Commutateur AMX5000 .............................................................................................. 12 Figure 2.
vi Guide d’installation et d’utilisation des commutateurs de la série AMX
vii LISTE DES TABLEAUX List of Tables Tableau 1.1 : Commutateurs KVM cibles dans un système de commutation AMX en cascade ........ 3 Tableau 3.1 : Voyants du panneau arrière de la console utilisateur ............................................. 20 Tableau 3.2 : Boutons de navigation dans l’interface OSCAR ...................................................... 21 Tableau 3.3 : Clavier PS/2 et ordinateur Sun ................................................................................ 29 Tableau 3.
viii Guide d’installation et d’utilisation des commutateurs de la série AMX
1 CHAPITRE 1 Présentation du produit Caractéristiques et avantages Les commutateurs de la série AMX™ d’Avocent permettent à plusieurs utilisateurs d’un système de commutation d’accéder à et d’utiliser simultanément un PC, des serveurs USB ou Sun et des équipements série.
2 Guide d’installation et d’utilisation des commutateurs de la série AMX Utilisateurs multiples Les commutateurs de la série AMX offrent des solutions de commutation à matrices, permettant à plusieurs utilisateurs d’accéder simultanément à différents serveurs et équipements série reliés au système. Par exemple, un système de commutation AMX comprenant quatre utilisateurs ayant accès à quatre serveurs différents constitue une matrice de type 4 x 4.
Chapitre 1 : Présentation du produit 3 Configuration en cascade continue Le système de commutation AMX permet aux utilisateurs de se connecter aux serveurs reliés aux commutateurs Avocent, eux-mêmes rattachés au commutateur AMX par sa voie locale. Le tableau 1.1 liste les commutateurs KVM de marque Avocent ou autre qui peuvent être montés en cascade continue dans un système de commutation AMX.
4 Guide d’installation et d’utilisation des commutateurs de la série AMX Interface utilisateur graphique OSCAR L’interface utilisateur graphique OSCAR vous permet de sélectionner tout ordinateur rattaché au système à partir de votre clavier ou de votre souris. Elle est compatible avec les fonctions de sécurité à plusieurs niveaux de protection par mots de passe, vous permettant ainsi de contrôler le niveau d’accès des utilisateurs à chaque serveur de votre centre de données.
Chapitre 1 : Présentation du produit Commutateur AMX5000 Commutateur AMX5010 Figure 1.0 : Comparaison des modèles de commutateurs AMX5000 et AMX5010 Console utilisateur AMX La console utilisateur AMX (consoles utilisateur AMX5100, AMX5110 et AMX5120) sert d’interface entre le commutateur AMX et les utilisateurs du système. Elle comporte l’interface OSCAR servant à la sélection et à l’administration des serveurs, ainsi qu’une fonction de compensation complète des mouvements vidéo.
6 Guide d’installation et d’utilisation des commutateurs de la série AMX Commutateur AMX5010 64 serveurs Câbles UTP Module AMIQ Console utilisateur AMX5110 16 utilisateurs Figure 1.1 : Configuration typique du système de commutation AMX Module intelligent AMX Le module intelligent AMX sert d’interface principale entre l’équipement relié (commutateur KVM ou serveur PS/2, Sun ou USB) et le système de commutation AMX.
Chapitre 1 : Présentation du produit 7 Câbles UTP Le système de commutation AMX utilise une technologie vidéo permettant de compenser les pertes de signaux dues aux câbles. Grâce à cette technologie, le commutateur AMX est compatible avec la plupart des types de câbles UTP et peut être utilisé dans des environnements comportant des combinaisons de différents types de câbles UTP et de tableaux de connexion.
8 Guide d’installation et d’utilisation des commutateurs de la série AMX • Circulation d’air réduite : l’équipement doit être monté en rack de façon à maintenir une circulation d’air suffisante pour garantir un fonctionnement en toute sécurité. • Charge mécanique : l’équipement doit être monté en rack en veillant à ce que la charge mécanique soit bien répartie, de sorte à éviter tout danger.
9 CHAPITRE Installation 2 Le système de commutation AMX assure la transmission des données du clavier, de la vidéo et de la souris entre les utilisateurs et les serveurs reliés via des câbles UTP (à paires torsadées non reliées) standards. Démarrage Avant d’installer le système de commutation AMX, reportez-vous aux listes ci-dessous afin de vous assurer que vous disposez bien de tous les éléments livrés avec le système de commutation AMX ainsi que de tous les éléments nécessaires à son installation.
10 Guide d’installation et d’utilisation des commutateurs de la série AMX Éléments nécessaires à l’installation L’installation du commutateur AMX requiert les éléments suivants : • Des câbles UTP pour chaque serveur et console utilisateur que vous désirez relier au système de commutation AMX • Une console utilisateur AMX5100, AMX5110 ou AMX5120 par utilisateur • Un module AMIQ par serveur ou un module AMIQ-SRL par équipement série Les éléments suivants peuvent également être nécessaires : • Le logi
Chapitre 2 : Installation 11 Installation d’un commutateur AMX Le commutateur AMX constitue le concentrateur principal du système de commutation AMX. Il permet d’interconnecter tous les utilisateurs et les ordinateurs. Figure 2.2 : Commutateur AMX5000 Figure 2.3 : Commutateur AMX5010 Montage en rack du commutateur AMX Vous pouvez choisir d’installer le commutateur AMX sur l’une des étagères de votre rack ou de le monter directement dans un rack conforme à la norme EIA (Electronic Industries Alliance).
12 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 2.4 : Schéma de montage en rack du commutateur AMX5000 Figure 2.5 : Schéma de montage en rack du commutateur AMX5010 Installation des supports de montage en rack 1. Retirez les deux vis latérales situées vers l’avant de l’appareil de chaque côté du commutateur AMX. 2. Alignez les orifices des supports avec les orifices des vis sur les côtés du commutateur AMX. 3.
Chapitre 2 : Installation 13 2. Connectez un terminal ou bien un ordinateur exécutant un logiciel d’émulation de terminal (tel que Hyperterminal®) à la voie du terminal du commutateur AMX, à l’aide du câble null modem fourni. Les paramètres du terminal doivent être configurés comme suit : 9 600 bauds, 8 bits, 1 bit d’arrêt, parité nulle et absence de contrôle de flux. 3.
14 Guide d’installation et d’utilisation des commutateurs de la série AMX Connexion des équipements au commutateur AMX Après avoir installé le commutateur AMX, vous pouvez y relier des serveurs ou des équipements série. Tous sont connectés au commutateur AMX par le biais des modules AMIQ. Pour obtenir des informations relatives à la connexion d’autres commutateurs KVM au commutateur AMX, référezvous à la section Installation d’un système de commutation AMX en cascade, de ce chapitre.
Chapitre 2 : Installation 15 Connexion d’équipements série au système de commutation AMX NOTA : Le module AMIQ-SRL est un équipement DCE uniquement compatible avec l’émulation de terminal VT100. 1. Munissez-vous du module AMIQ-SRL. 2. Branchez le connecteur série à 9 broches du module AMIQ-SRL sur la voie série de l’équipement à relier au commutateur AMX. 3. Reliez une extrémité du câble CAT 5 au connecteur RJ-45 du module AMIQ-SRL.
16 Guide d’installation et d’utilisation des commutateurs de la série AMX Prise d’alimentation en courant Connexions aux commutateur AMX et serveur local Connecteurs Voie série KVM Figure 2.9 : Panneau arrière des consoles utilisateur AMX5110 et AMX5120 Connexion des utilisateurs au système de commutation AMX 1. Placez la console utilisateur AMX à proximité du moniteur que vous souhaitez connecter.
Chapitre 2 : Installation 17 Connexion d’un ordinateur local au système de commutation AMX 1. Identifiez un module AMIQ adapté au serveur que vous souhaitez relier. 2. Branchez les connecteurs de clavier, de moniteur et de souris du module AMIQ dans les voies appropriées à l’arrière du serveur sélectionné. 3. Branchez une extrémité du câble UTP dans la voie RJ-45 du module AMIQ. Acheminez le câble jusqu’à la console utilisateur AMX et connectez l’autre extrémité à la voie serveur RJ-45.
18 Guide d’installation et d’utilisation des commutateurs de la série AMX 2. Branchez une extrémité d’un câble UTP dans une voie serveur du concentrateur. Acheminez le câble jusqu’au prochain commutateur à inclure dans le système en cascade et branchez-le dans une des voies utilisateur disponibles. Continuez ce procédé jusqu’à ce que toutes les voies utilisateur des commutateurs AMX à monter en cascade soient connectées. 3.
19 CHAPITRE 3 Opérations de base Mise sous tension et voyants Commutateurs AMX5000 et AMX5010 Les panneaux avant des commutateurs AMX5000 et AMX5010 comportent trois groupes de voyants. Chaque voyant vert du groupe de gauche correspond à une voie serveur. Ils s’allument lorsque le système ou le commutateur AMX monté en cascade relié est sous tension. Figure 3.1 : Commutateur AMX5000 Les voyants verts et orange du groupe central indiquent l’état de la connexion LAN.
20 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 3.2 : Console utilisateur AMX5110 Le panneau arrière des consoles utilisateur AMX5110 et AMX5120 comporte deux voyants, un vert et un jaune, rattachés à chaque connecteur de voie UTP. Le voyant vert indique l’état de connexion de la voie. Le voyant jaune indique l’état d’activité de la voie. Les voyants des voies UTP du panneau arrière sont décrits dans le tableau suivant. Tableau 3.
Chapitre 3 : Opérations de base 21 Elle comporte cinq onglets principaux : Target (cible), User (utilisateur), Console (console), Admin (administrateur) and ? (aide). Les boutons fléchés permettent de naviguer facilement d’un écran de l’interface à l’autre, comme décrit dans le tableau suivant. Tableau 3.
22 Guide d’installation et d’utilisation des commutateurs de la série AMX Scan (Mode balayage) Le mode balayage vous permet de contrôler plusieurs serveurs de façon séquentielle. Le balayage est interrompu dès qu’une activité du clavier ou de la souris est détectée, permettant ainsi à d’autres utilisateurs d’utiliser un équipement relié. Pour de plus amples informations sur la fonction de balayage, référez-vous à la section Sélection des serveurs dans ce chapitre.
Chapitre 3 : Opérations de base Figure 3.3 : Onglet User de l’interface OSCAR 3. Saisissez votre mot de passe actuel dans le champ Current. 4. Saisissez votre nouveau mot de passe dans le champ New ainsi que dans le champ de confirmation (Confirm). Celui-ci doit comporter au moins six caractères. Cliquez sur Apply (appliquer). NOTA : En cas de perte de votre mot de passe, contactez le service d’assistance technique d’Avocent. 5.
24 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 3.4 : Écran Target Flag de l’interface OSCAR 4. Cliquez sur le bouton Name (nom) pour afficher le nom du serveur connecté sur l’indicateur de l’équipement cible. - ou Cliquez sur le bouton UID pour afficher l’identifiant UID du serveur connecté sur l’indicateur de l’équipement cible. 5. Cliquez sur le bouton à double flèche du champ Text pour afficher la liste déroulante correspondante.
Chapitre 3 : Opérations de base 25 11. Cliquez-déplacez la barre de titre de l’indicateur de l’équipement cible pour l’amener à l’emplacement souhaité. 12. Lorsque celui-ci est à l’emplacement souhaité, cliquez sur le bouton X pour fixer la position et revenir à l’écran Target Flag. NOTA : Appuyez sur Echap pour revenir à l’écran Target Flag sans enregistrer la nouvelle position. 13. Cliquez sur Apply pour appliquer et enregistrer les modifications apportées à l’indicateur. 14.
26 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 3.7 : Écran Change Hotkey de l’interface OSCAR 7. Cliquez sur le bouton fléché « bas » et sélectionnez la séquence de raccourcis clavier désirée dans la liste déroulante. Cliquez sur OK. NOTA : Si la séquence de raccourci est déjà attribuée à un autre serveur, vous pouvez, au choix, ré-attribuer la séquence en question ou revenir à l’écran Change Hotkey pour sélectionner une autre séquence de raccourci.
Chapitre 3 : Opérations de base 27 Alt+Alt (L-R) (droite ou gauche) Shift+Shift (L-R) (Maj+Maj (droite ou gauche)) Shift-Shift (L) (Maj+Maj (gauche)) Shift+Shift (R) (Maj+Maj (droite)) Scroll Lock+Scroll Lock (Arrêt défil+Arrêt défil) Pour plus d’informations, consultez la section Gestion de la console au Chapitre 4. Onglet Admin L’onglet Admin comporte des options de modification des informations relatives aux utilisateurs et aux serveurs.
28 Guide d’installation et d’utilisation des commutateurs de la série AMX 2. Cliquez sur l’onglet Target et sélectionnez le mode d’accès approprié : Shared, Private, Scan ou Maintain. 3. Cliquez deux fois sur le nom du serveur. -ouCliquez sur le nom du serveur, puis sur le bouton Start (démarrer). 4. Pour vous déconnecter d’un serveur, lancez l’interface OSCAR et cliquez sur le bouton Clear (effacer) ou connectez-vous à un autre serveur. Balayage d’un système de commutation AMX 1.
Chapitre 3 : Opérations de base 29 laquelle chaque voie reste à l’écran, ou durée d’affichage, est réglable et peut être modifiée à tout moment à l’aide de l’onglet User. La durée d’affichage par défaut est de trois secondes. Pour stopper le balayage, appuyez deux fois sur Ctrl. L’écran réapparaît. 4. Cliquez sur le bouton Stop. 5. Cliquez sur Close (fermer) pour quitter l’onglet Target.
30 Guide d’installation et d’utilisation des commutateurs de la série AMX Tableau 3.
31 CHAPITRE 4 Opérations avancées Gestion des utilisateurs Le système de commutation AMX peut être configuré pour inclure jusqu’à 128 utilisateurs. Chacun d’entre eux dispose d’un identifiant et d’un mot de passe uniques et de droits d’utilisateur variés (droits illimités, lecture seule ou aucun droit) sur les serveurs reliés au commutateur AMX.
32 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 4.2 : Écran Add User de l’interface OSCAR. 5. 6. 7. Saisissez le nom d’utilisateur dans le champ Username (nom d’utilisateur). Saisissez le mot de passe de l’utilisateur dans le champ Password puis dans le champ Confirm password. Cliquez sur OK. Modification d’un utilisateur 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. 3. 4. Cliquez sur l’onglet Admin.
Chapitre 4 : Opérations avancées 6. 7. 33 Cliquez sur OK. Cliquez sur Cancel pour revenir à l’écran User Admin. Connexion forcée des utilisateurs 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. 3. 4. 5. Cliquez sur l’onglet Admin. Cliquez sur le bouton fléché « bas » pour afficher l’écran User Admin. Sélectionnez Admin dans la liste et cliquez sur le bouton Edit user. L’écran Edit User s’affiche.
34 Guide d’installation et d’utilisation des commutateurs de la série AMX Figure 4.4 : Écran User Right de l’interface OSCAR 6. Pour modifier les droits d’accès d’un utilisateur à un seul serveur, cliquez sur le serveur cible dans la liste des serveurs disponibles. Sélectionnez le niveau d’accès approprié : none (aucun), view (lecture seule) ou full (droits illimités).
Chapitre 4 : Opérations avancées 35 Figure 4.5 : Écran Device Admin de l’interface OSCAR Modification d’un équipement (monté en cascade normale) 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. Cliquez sur l’onglet Admin. L’écran Device Admin s’affiche. NOTA : Le nombre d’équipements qui s’affichent sur l’écran dépend des droits attribués à l’utilisateur. Seuls les équipements reliés au système de commutation AMX et sous tension peuvent être modifiés.
36 Guide d’installation et d’utilisation des commutateurs de la série AMX Les champs UID et Type ne peuvent pas être modifiés. Le champ Type affiche le type d’équipement modifié, ainsi que l’une des informations suivantes : 5. 6. 7. 8. 9. • PS/2 Single-Port • SUN Single-Port • USB Single-Port • Serial Single-Port • MDM Server Saisissez le nouveau nom que vous souhaitez attribuer à l’équipement dans le champ Name (1 à 15 caractères).
Chapitre 4 : Opérations avancées 37 NOTA : Le nombre d’équipements qui s’affichent sur l’écran dépend des droits attribués à l’utilisateur. Seuls les équipements reliés au système de commutation AMX et sous tension peuvent être modifiés. Seuls les utilisateurs connectés en tant qu’administrateurs système peuvent modifier tous les équipements à l’exception du Matrix System. 3. 4. 5. Sélectionnez l’équipement à modifier dans la liste déroulante. Cliquez sur le bouton Edit Device.
38 Guide d’installation et d’utilisation des commutateurs de la série AMX 6. Cliquez sur Close pour revenir à l’écran Device Admin. Affichage des informations relatives au module AMIQ 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. 3. Cliquez sur l’onglet Admin. L’écran Device Admin s’affiche. Sélectionnez le module AMIQ dont vous souhaitez afficher la version ainsi que les informations relatives à la configuration et à la connexion. Cliquez sur le bouton Edit Device.
Chapitre 4 : Opérations avancées 39 Configuration de la console 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. Cliquez sur l’onglet Console. L’écran Status (état) affiche l’état de connexion de la console utilisateur AMX. Figure 4.9 : Écran Status de l’interface OSCAR 3. Cliquez sur le bouton de navigation fléché « bas » pour afficher l’écran Configure. Figure 4.10 : Écran Configure de l’interface OSCAR 4.
40 Guide d’installation et d’utilisation des commutateurs de la série AMX 5. Si le champ Type est actif, cliquez sur le bouton avec la double flèche et sélectionnez Standard ou Pinnacle FAK. Lorsque vous apportez une modification dans le champ Type, le texte modifié apparaît surligné en bleu. NOTA : Le mot Standard correspond à tout type de clavier.
Chapitre 4 : Opérations avancées 41 Activation et configuration de l’option de verrouillage NOTA : L’option Force User Login doit être activée et l’utilisateur Admin doit être connecté pour pouvoir activer l’option de verrouillage. Référez-vous à la section Maintenance utilisateur au Chapitre 3 pour plus d’informations. 1. Appuyez deux fois sur Ctrl pour lancer l’interface OSCAR. 2. 3. 4. Cliquez sur l’onglet Console. Cliquez sur le bouton fléché « bas » pour afficher l’écran Configure.
42 Guide d’installation et d’utilisation des commutateurs de la série AMX Introduction d’un commutateur externe Le système AMX permet de contrôler les opérations de commutation au sein du système de commutation à l’aide d’un équipement externe au réseau, par le biais d’une connexion SNMP. Les droits d’accès aux commandes SNMP sont attribués à l’utilisateur « snmpUser ».
Chapitre 4 : Opérations avancées 43 Forcer un utilisateur à établir ou interrompre une connexion NOTA : Respectez les règles suivantes pour un fonctionnement optimal de la fonction de connexion imposée : - L’utilisateur entrant la commande et celui de la console cible doivent tous deux avoir accès au serveur. - Toutes les connexions forcées doivent être effectuées en mode partagé. - Chaque console utilisateur et chaque module AMIQ doit avoir un nom unique.
44 Guide d’installation et d’utilisation des commutateurs de la série AMX
45 CHAPITRE 5 Utilisation de la voie terminal Accès au menu Terminal Vous pouvez configurer chaque commutateur AMX5000 et AMX5010 individuellement via la voie Terminal. Toutes les commandes du terminal sont accessibles à partir d’un terminal ou d’un PC exécutant un logiciel d’émulation de terminal.
46 Guide d’installation et d’utilisation des commutateurs de la série AMX Gestion du système Le commutateur AMX utilise des adresses IP pour communiquer avec le logiciel AMWorks et synchroniser toutes les bases de données du commutateur AMX. Attribuez un identifiant unique à chaque configuration de manière à pouvoir connecter et gérer plusieurs configurations de systèmes de commutation AMX sur le même sous-réseau.
Chapitre 5 : Utilisation de la voie terminal 47 • Activation et désactivation SNMP • Définition des noms de communauté des champs read (lire), write (écrire) et trap (interruption) • Définition et suppression des adresses IP de destination des interruptions (4 maximum) • Activation et désactivation des interruptions SNMP Configuration du protocole SNMP 1. Dans le menu Main (Principal) de la console série, appuyez sur 4 pour sélectionner SNMP Configuration. Le menu SNMP Configuration s’affiche.
48 Guide d’installation et d’utilisation des commutateurs de la série AMX Gestion SNMP d’objets de commutation AMX Le protocole SNMP vous permet de contrôler et de gérer des objets de la base de données MIB (Management Information Base) spécifiques aux commutateurs AMX5000 et AMX5010. Référezvous au tableau 5.2 pour obtenir une description des groupes d’objets MIB du système AMX. Tableau 5.
49 ANNEXES Annexes Annexe A : Spécifications techniques Tableau A.
50 Guide d’installation et d’utilisation des commutateurs de la série AMX Tableau A.
ANNEXES 51 Tableau A.
52 Guide d’installation et d’utilisation des commutateurs de la série AMX Tableau A.
ANNEXES 53 Tableau A.
54 Guide d’installation et d’utilisation des commutateurs de la série AMX Annexe B : Utilisation des modules AMIQ-SRL Le module AMIQ-SRL est un convertisseur série/VGA permettant aux équipements compatibles avec VT100 d’être visualisés par la voie locale du commutateur AMX. Les données série proprement dites ne sont pas disponibles mais uniquement visibles.
ANNEXES 55 • Enter Sends (Envoi de touches) : permet de définir les touches à transmettre lorsque vous appuyez sur Entrée. Les options disponibles sont (Entrée) ou (Entrée-Saut de ligne). • Received (Reçu) : permet de définir la manière dont le module interprète un caractère Entrée reçu. Les options disponibles sont (Entrée) ou (Entrée-Saut de ligne). • Background (Arrière-plan) : permet de changer la couleur d’arrière-plan de l’écran.
56 Guide d’installation et d’utilisation des commutateurs de la série AMX • History Key Sequence (Raccourci du mode historique) : permet de définir la combinaison de touches activant le mode History (Historique). La combinaison de touches par défaut est Ctrl-F9. • Clear History Key Sequence (Raccourci de l’effacement d’historique) : permet de définir la combinaison de touches vidant la mémoire tampon de l’historique lorsque le mode History (Historique) est activé.
ANNEXES 6. 57 Une fois terminé, appuyez sur Entrée pour enregistrer les modifications et quitter l’écran Macro Configuration. - ou Appuyez sur Echap pour quitter l’écran Macro Configuration sans enregistrer vos modifications. Utilisation du mode History Le mode History vous permet d’examiner le tampon de l’historique, qui contient les événements survenus. Le module AMIQ-SRL dispose d’un tampon de sortie de 240 lignes au minimum (équivalant à 10 écrans).
58 Guide d’installation et d’utilisation des commutateurs de la série AMX Brochage du module AMIQ-SRL Le tableau suivant dresse la liste des broches du module AMIQ-SRL. Tableau B.
ANNEXES 59 Annexe C : Assistance technique Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez la procédure ci-après afin de bénéficier d’une aide le plus rapidement possible : 1. Vérifiez la section appropriée du manuel pour voir si le problème peut être résolu à l’aide des procédures indiquées. 2. Consultez le site www.avocent.
60 Guide d’installation et d’utilisation des commutateurs de la série AMX Annexe D : Paramètres de configuration de l’écran Edit Device de l’interface OSCAR Tableau D.1 : Commutateur KVM Auto View Paramètres de configuration de l’écran Edit Device Target (équipement cible) Commutateur AutoView Ports (Voies) 4, 8 Hotkey (séquence de raccourci clavier) NumLock + « - » (Verr num + « - »), NumLock + « + » (Verr num + « + »), Ctrl + « ~ » Tableau D.
ANNEXES 61 Tableau D.
62 Guide d’installation et d’utilisation des commutateurs de la série AMX Tableau D.7 : IBM C2T Paramètres de configuration de l’écran Edit Device Target (équipement cible) IBM C2T Ports (Voies) jusqu’à 32 Hotkey (séquence de raccourci clavier) NumLock–NumLock (Verr num – Verr num) Tableau D.
63 INDEX A Commutateurs i Aide en ligne 3 Ajout d’un utilisateur 31 Alimentation 12 Alimentation de secours (sans coupure) 7 AMIQ Commutation à matrices 2 Commutation rapide 40 Compensation des mouvements vidéo 1 Configuration clavier 39 Configuration des droits d’accès utilisateur 33 module -vSN 36 Configuration en cascade continue 3 module -xSN 36 Configuration/Modification du mot de passe 46 Assistance technique 59 Configurations clavier console utilisateur AMX 36, 40 C Connexion Câbles UTP
64 Guide d’installation et d’utilisation des commutateurs de la série AMX Déconnexion 41 Installation éléments nécessaires 10 Digital Data Channel 6 Durée de balayage 22 Introduction forcée d’un commutateur externe 42 E L Économiseur d’écran 41 LDAP Écran Add User 32 Voir Lightweight Directory Access Protocol 2 Écran Change Hotkey 26 Lightweight Directory Access Protocol 2 Écran d’information Ligne de commandes 42 affichage du module AMIQ 38 Logiciel AMWorks 1, 4 affichage du serveur MDM 3
Index informations relatives à l’équipement 37 Module AMIQ 6 affichage des informations 38 interface utilisateur graphique 4, 20 spécifications techniques 52 onglet Console 26 voyants 20 onglet Target 21 suppression d’un utilisateur 33 Module AMIQ-SRL 6 Target Flag 24 brochage 58 compatibilité multilingue 58 configuration 54 création de macros 56 P Partage 2 modification 46 modes 54 utilisation 54 Période d’inactivité 41 utilisation du mode History 57 R voyants 20 Modules MDM AMIQ 34 Mot de
66 Guide d’installation et d’utilisation des commutateurs de la série AMX Spécifications techniques 49, 53 Température ambiante 7 Supports de montage en rack Terminal Applications configuration du mot de passe 46 installation 13 Suppression d’un utilisateur 33 Touches de commandes du mode History 57 Surcharge du circuit 8 Traduction du clavier 29 Système de commutation AMX connexion d’un ordinateur local 17 connexion de serveurs 15 U Utilisateur SNMP ajout 42 connexion des équipements série 16 c
Index 67
68 Guide d’installation et d’utilisation des commutateurs de la série AMX
AMX™ Switch Series For Technical Support: Installer/User Guide Guide d’installation et d’utilisation Email: support@avocent.com www.avocent.com Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA Tel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.