72 Cyclades ACS 6000 Advanced Console Server Installation/Administration/User Guide
Set telephone extension option
This command enables/disables “line-in-use” and “extension pickup” options.
If the line is in use and the modem receives an ATDT command to dial out, the modem will not go
off hook and will display the “LINE-IN-USE” result code. If the modem is off hook and the
extension is picked up, the modem will drop the connection and display the “OFF-HOOK
INTRUSION” result code.
AT S registers
The S registers use the following format: ATSr=n<CR> where the “r” is the S register number and
“n” is the parameter to set it to. To read the current contents of an S register, issue an
ATSr?<CR>
command where “r” is the register in question. The modem will then display the value of the S
register.
V92
downstream
V92 56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667,
45333, 42667, 41333,, 40000, 38667, 37333, 36000, 34667,
33333, 32000, 30667, 29333, 28000
V92
upstream
V92 48000, 46667, 45333, 42667, 41333,, 40000, 38667, 37333,
36000, 34667, 33333, 32000, 30667, 29333, 28000, 26667,
25333, 24000
Table D.3: +MS Command Supported Rates (Continued)
Modulation Carrier Possible Minimum, Maximum, Receive and Transmit Rates
Table D.4: Set Telephone Extension Options
-STE=n Value Extension Pickup Line-In-Use
0 (default) Disabled Disabled
1 Disabled Enabled
2 Enabled Disabled
3 Enabled Enabled
Table D.5: AT S Registers
Register Range Units Default Description
S0 0-255 Rings 0 Ring to answer on. ATS0=1<CR> means
answer call on first ring detected.
S1 0-255 Rings 0 Number of rings counted.
S2 0-127 ASCII 43 Escape code character.