Appendices 65
2. Select DSView Settings - Dial-up.
3. Select Modem Type - Analog.
4. Enter the phone number for the ACS 6000 console server you want to use.
5. Enter the PPP User and select the PPP Auth Protocol in the appropriate fields.
6. For dial-in with callback, enable the dial-back checkbox.
7. Select DSView Settings - Dial-up - PPP Password, then enter and confirm the password
needed to access the ACS 6000 console server.
8. Select DSView Settings - Dial-up - IP Addresses.
9. Click Generate Automatically to set the IP address automatically, or enter the PPP Local IP
address and Appliance IP address manually.
To configure a console server to receive the dial-up connection within the DSView
3 software:
1. In a Units view window containing appliances, select the ACS 6000 console server you want
to configure.
2. For a modem attached to a serial port, select Ports - Serial Ports, then select the port that
contains the attached modem. Click Set Dial-In.
-or-
For a modem attached to an auxiliary port, select Ports - Auxiliary Ports, then select the port.
Click Set Dial-In.
-or-
For an internal modem, select Ports - Auxiliary Ports and select the modem.
-or-
For a pluggable device modem, select Pluggable Devices and select the modem.
3. For dial-in with callback, click Ports - Dial-in Profile - Devices and select the modem to be
used for dial-in.
-or-
For dial-in with a one-time password (OTP), click Ports - Dial-in Profile - Secure Dial-in -
Settings and select Enable next to the Log In To Appliance field.
4. Select Accept Configuration from Remote Peer in the PPP Address field.
5. Select By Appliance in the PPP Authentication field and set the protocol.
-or-
For dial-in with callback, select By Remote Peer in the PPP Authentication field and select the
protocol.
6. Click Ports - Dial-in Profile - Settings and select Disable in the Log In To Appliance field.
(You may select Enable if you want to get terminal access besides PPP or Callback if you want