User guide
52 Cyclades ACS 6000 Advanced Console Server Installation/Administration/User Guide
Event Destinations
The ACS 6000 console server will generate notifications for a wide variety of events. You can
configure the console server to direct or store those event notifications to various destinations for
immediate use or for analysis later.
To configure Event Destinations:
1. Click on Event and Logs - Event Destinations.
2. Under the Syslog heading, use the drop-down menu to select the Facility.
3. Select Remote Server - IPv4 to enable syslog messages to be sent to one or more remote IPv4
syslog servers, and enter the IPv4 Address or Hostname. Separate multiple server addresses by
commas.
-or-
Select Remote Server - IPv6 to enable syslog messages to be sent to one or more remote IPv6
syslog servers, and enter the IPv6 Address or Hostname. Separate multiple server address by
commas.
4. Select Appliance Console to send messages to the ACS 6000 console server’s console.
5. Select Root Session to send syslog messages to all sessions where you are logged in as root
user.
6. Under the SNMP Trap heading, enter the name of the community defined in one or more of the
SNMP trap servers in the Community field then enter the IP addresses of up to five servers in
the server fields.
7. Under the SMS heading, enter the SMS Server, Port and Pager Number information in the
appropriate fields.
8. Under the Email heading, enter the Server, Port and Destination Email information in the
appropriate fields.
9. Under the DSView heading, enter the IP address of the DSView 3 server where event
notifications will be sent in the DSView 3 server field. Enter the syslog server port number for
the DSView 3 server, the SSH information and the buffer warning information in the
appropiate fields.
10. Click Save.
Data Buffering
To configure Data Buffering:
1. Select Events and Logs - Data Buffering.
2. Enter the segment size in kilobytes and spare segments in the Local Data Buffering Settings
section.
3. In the NFS Data Buffering Settings section, enter the following information: NFS Server, NFS
Path, Segment Size (Kbytes) and Spare Segments.