4.2 T-Bar Calibration
The T-Bar of the video switcher may happen to misalignment, when the origin of the coordinates offset the
T-Bar calibration is necessary before using.
1) Power off the video switcher, and then press and hold button 1 and 2 of PVW at same time. Hold the
buttons until all calibration complete.
2) Turn on the video switcher, then the LED indicators of T-Bar will be turn on from bottom to top.
3) Adjust the T-Bar to A-BUS or B-BUS until all LED indicators turn on. Below image is an example of the
LED indicators status when switching the T-Bar from B-BUS to A-BUS.
4) Then the T-Bar calibration is finished, and release the button 1 and 2.
4.3 PGM & PVW Switching
4.3.1 PGM & PVW Channel Selection
Below 1-6 buttons from PGM and PVW are corresponding with the 6 windows in the below of the
multiview layout. The selected button from PGM turns on to red LED, and the selected button from PVW
turns on to green LED.
The default sources of PGM and PVW are SDI 2 and SDI 1 when turn on the video switch. When
operating the AUTO or T-Bar transition, both LED indicators are turning red.
The selected PGM source will be circled in red border, while the selected PVW source will be circled in
green border.