Operation Manual
Advanced Configuration 199
7. Ensure that Association Status is set to Enabled.
To change the displayed status, select Status, select the desired
status from the pop-up display, then press <Enter>.
8. Optionally, do the following to modify the connect and
disconnect timer values:
8a. Enter a new value, in seconds, in the Connect Delay
Timer field, then press <Enter>.
When the primary call destination failed, this value is the
number of seconds to delay before attempting to connect to
the backup call destination.
8b. Enter a new value, in seconds, in the Disconnect Delay
Timer field, then press <Enter>.
When the backup call destination is up, and the primary call
destination reconnects, this value is the number of seconds
to delay before disconnecting the backup call association.
9. Press <Esc> to return to the Internetworking Configuration
screen; save your changes when prompted.
The backup call association you configured is listed in the
Configured Backup Call Associations screen.
10. To configure another interface, repeat Step 2 through Step 9.
11. If you want these changes to take effect immediately, select
Reinitialize System.
If you want to configure other parameters, do so now, then
reinitialize the system when you are finished.
Advanced.pm6 27.05.97, 11:15199