Operation Manual

192 NetWare MultiProtocol Router for ISDN 3.1 Installation and ISDN Configuration Guide
Detailed information on configuring ISDN Call Destinations is
given in Chapter 7.
1a. Set the parameter Call Type to Permanent.
1b. Set the Retry Mode to Retry All Failures.
1c. Set the Retry Limit Handling to Continuous At Limit.
1d. Set the Retry Interval Limit to 8 seconds.
2. Configure Source Route Bridge.
Parameter path: Select Protocols > Select Source Route Bridge.
2a. Set the Bridge Status to Enabled.
2b. Set the Bridge Number.
Both half-bridges must have the same bridge number.
3. Bind the Source Route Protocol to a WAN interface.
Parameter path: Select Bindings.
3a. Press <Ins>, then select Source Route Bridge from the
list of configured protocols.
3b. Select the interface to which you are binding the proto-
col.
3c. Enter the Ring Number of the remote bridge.
3d. Set Virtual WAN Ring to On.
3e. Select the WAN call destination that connects the
bridge to the other bridge.
4. Press <Esc> to return to the Internetworking Configuration
screen; save your changes when prompted.
5. Select the Reinitialize System command to bring configura-
tion changes into effect.
Sourcero.pm6 27.05.97, 21:15192