Operation Manual
Number Configuration
36 Netware Connect for ISDN – 4 Configuration
ISDN-Controller Configuration (load nwcicon, “Configure ISDN-Control-
lers”, select controller)
RNSI Configuration (load nwccon, “Configure Services / RNSI / Parame-
ters for ISDN-Controller NWCI1”)
Example 2: Connected to a PBX Extension Using DSS1 in Berlin, Germany,
with DDI Number 789 and Outside Dialing Prefix 0
Global Configuration (load nwcicon, “Configure Global Parameters”)
Configuration of ISDN-Controller NWCI1
I/O Base Address: 150
Interrupt Request Level: 5
ISDN D Channel Protocol: DSS1
Connected to a PBX: Disabled
Outside Line Access: 0
...Number Length: 4
Configuration of RNSI Parameters for
ISDN-Controller NWCI1
Country Code: 49
Area Code: 030
ISDN Number: 5567892
PBX Extension:
MSN: 5567892
Expert Configuration: (view or modify)
Configuration of Global Parameters
24h Maximum Physical Connection Time
per NWCI Port: Disabled
24h Maximum Charge Units: Disabled
ISDN Line Management Daily Log: sys:etc/nwciline.
*
ISDN Accounting Daily Log: sys:etc/nwciacct.
*
International Dialing Prefix: 00
nwci2.1.book Seite 36 Donnerstag, 13. Januar 2000 11:36 11