Operation Manual
ISDN-Controller B1 v3.0 with CAPI for the CAPI Manager
ISDN-Controller B1 v3.0 – 10 Installation in Novell NetWare 67
10.5 ISDN-Controller B1 v3.0 with CAPI for
the CAPI Manager
Proceed as follows to configure and start operation of the
AVM ISDN-Controller B1 v3.0 with CAPI for the CAPI Manager:
1. Enter the following command at the system console:
load inetcfg
2. The “Internetworking Configuration” window appears.
Select the “Boards” entry and press “Return”.
A list displays all available ISDN-Controllers.
3. To bind the ISDN-Controller into the operating system
press the “Ins” key.
4. In the “Select a Driver” dialog, select the “WHSMCAPI”
entry and press “Return”.
5. In the next window, assign a name for the ISDN-Control-
ler B1 v3.0, such as B1ISA, and press “Return”.
6. Configure the ISDN-Controller in the “WHSMCAPI Board
Configuration” window.
Move the highlight to “Select to View” and press “Re-
turn”.
7. When prompted to choose whether the ISDN-Controller
should be loaded automatically, select “Yes”.
8. In the next dialog, select the ISDN-Controller “AVMB1”
and press “Return”.
9. Then enter your parameters:
– Interrupt
– I/O address
– Maxports (fixed at 2)
– Switch Type (D-channel protocol)
– Line Config (MTP= multipoint or PPT= point-to-point)
– Automatic Data Compression