Operation Manual

Configuring the ISDN-Controller B1 v3.0
58 ISDN-Controller B1 v3.0 9 Installation in MS-DOS
9.2 Configuring the ISDN-Controller
B1 v3.0
The I/O address set using the jumper must match the entry
in the controller software. Proceed as follows to enter the I/O
address:
1. Open the B1 Setup program. The following dialog ap-
pears on the screen:
Dialog of the B1 Setup program
2. In the first input field, enter the I/O address set on the
controller.
Either change the specified value with the space bar, or
view an overview of the available values by pressing the
Tab key.
Select the desired I/O address and activate it by press-
ing Return from the input field.
3. In the second input field, enter a new value for the inter-
rupt.
Press the space bar or the Tab key to select another
value.
The interrupts 10, 11, 12 and 15 can be used only if the
ISDN-Controller was inserted in a 16-bit slot.
4. Save your entries by pressing Ctrl+Home or Return.
HB_B1V30.book Seite 58 Mittwoch, 7. Februar 2001 3:19 15