Operation Manual

Error messages in MS-DOS
100 Controller B1 v3.0 16 Troubleshooting
Remedy: Run theB1 Unload program from the AVM pro-
gram group to unload the ISDN-Controller and then start the
test program again.
Error messages in MS-DOS
Error message: Controller-xx with I/O address <xxx> could
not be found
Possible cause: The position of the jumper that sets the I/O
address on the ISDN-Controller does not correspond to the
entry in the B1 Setup program, the I/O address is used by
another hardware device (such as a network adapter), or the
hardware is not installed.
Remedy: Check which I/O address is available in your com-
puter and set the jumper on the ISDN-Controller accordingly
(see the section Setting the I/O Address on page 14). Then
enter the new I/O address in the driver software by starting
the B1 Setup program from the AVM program group.
Then reload the ISDN-Controller with ibase.bat.
Error message: Installation Error. Interrupt <xx> not
available.
Possible cause: The AVM ISDN-Controller B1 v3.0 and anoth-
er hardware device (like a sound card) are set to the same in-
terrupt.
Remedy: Check which interrupts (IRQs) are available in your
system by using the MSD.EXE program in the Windows direc-
tory. Then start the B1 Setup program from the AVM pro-
gram group and define another interrupt for the ISDN-Con-
troller. Then reload the ISDN-Controller with ibase.bat.
Error message: Error in the configuration file. Incorrect B1
controller type.
Possible cause: Different types of controllers (ISDN-Control-
lers for the ISA and PCI buses) are combined in your system.
During the installation of the additional controller, the file
ISDNLOAD.CFG was not changed correctly.
HB_B1V30.book Seite 100 Mittwoch, 7. Februar 2001 3:19 15