63 
D-2.5 ACK Type E 
ACK Byte + LB + EXTI + VIDI + AUDI + PLUG +.....+ CRC Byte 
Name  Bit 7  Bit 6  Bit 5  Bit 4  Bit 3  Bit 2  Bit 1  Bit 0 
AB 
ACC  0  0  Device ID (0 - 31) 
LB 
Length for the total data bytes (EXINF +.....+ DTMAX) 
EXINF 
LBMAX 
0 0 0 0 0 FWVER
VEINF 
EDID 0 0 0 0 0 0 0 
AEINF 
DTUF DELAY  0  0  SW  TRE  BASS  VOL 
PLUG 
0 0 0 0 AOPD VOPD AIPD VIPD 
DTMAX 
Delay Time Maximum (unit: 100 ms) 
CB 
CRC 
AB & CB: These are the same as the ACK Type A. 
LB: LB value is the total length of the data bytes, not include the AB, LB and CB. 
EXINF: Device extended information 
LBMAX - defines the maximum LB value of the variable length command 
0 - The maximum LB is 64 Bytes (default) 
1 - The maximum LB is 128 Bytes 
2 - The maximum LB is 254 Bytes (255 is reserved)   
3 - Reserved 
The LB value of the Ack packet is not limited by LBMAX. 
If the extended information does not exist, the default maximum length is 128. 
FWVER - Firmware version command flag. (Request 0x31) 
1 - Support Firmware version command. 
0 - Not support Firmware version command. 
VEINF: Video Extend Information 
EDID - Input EDID type select command flag. (Request 0x20 and 0x21) 
1 - Support Input EDID type select command. 
0 - Not support Input EDID type select command. 
AEINF: Audio Extend Information 
VOL - Volume and Mute command flag. (Request from 0x10 to 0x13) 
1 - Support Volume and Mute command. 
0 - Not support Volume command. 
BASS - Bass command flag. (Request 0x14 and 0x15) 
1 - Support Bass command. 
0 - Not support Bass command. 