Distribution Amplifier (DA)—User Manual 
59 
D-2 Device ACK Packet 
When the device receives supported commands comes from the host, and then will 
response with following ACK: 
Table – ACK Type List 
Ack Type  Byte 1 Byte 2  Byte 3 Byte 4 Byte 5 Byte 6  …  Last Byte
Type A 
AB             CB 
Type B 
AB  LB  Index 1 Value 1 Index 2 Value 2 
… 
CB 
Type C 
AB  LB  Data 1 Data 2      CB 
Type D 
AB LB INF OP  IP Name 1 
… 
CB 
Type E 
AB LB EXINF VEINF AEINF PLUG 
… 
CB 
D-2.1 ACK Type A 
ACK Byte + CRC Byte (Total 2 Bytes)   
Name  Bit 7  Bit 6  Bit 5  Bit 4  Bit 3  Bit 2  Bit 1  Bit 0 
AB 
ACC  0  0  Device ID (0 – 31) 
CB 
CRC 
ACC: The devices acknowledge status. Accept or Reject. 
1: device accepts this request. (ACK; acknowledge) 
0: device rejects this request. (NAK; negative acknowledge) 
) The device sends the Nak packet is always 2 bytes. (NAK + CRC) 
0: Reserve, Always 0. 
1: Identifier, Always 1. 
Device ID: Device id ranges from 0 to 31. (Please refer to device’s user manual) 
CRC: Device always sends the CRC code to follow the last byte. 