4-65
The “Reset Pad Count” button
After scanning approximately 50,000 pages (the number
varies based on type of scanner) through the Auto Document
Feeder (ADF), the ADF pad may be worn out and you may
experience problems with document feeding. In this case, it is
highly recommended to replace the ADF pad with a new one.
(Please refer to the manual for proper replacing procedure.)
For ordering the ADF pad, please consult your nearest dealer.
After replacing the ADF pad, click the “Reset Pad Count
button to reset the pad count.
The “Reset Roller Count” button
After scanning approximately 200,000 pages (the number
varies based on type of scanner) through the ADF, the ADF
roller may be worn out and you may experience problems with
document feeding. In this case, it is highly recommended to
replace the ADF roller with a new one. (Note the replacement
of the ADF roller has to be performed only by authorized
service center. Therefore, please return your scanner for
roller replacement.) After replacing the ADF roller, click the
Reset Roller Count” button to reset the roller count.
Note
The lifetime and the replacing procedure vary based on type
of scanner.