82
Pr o 64 Ne t w o r k Ma N a g e r Us e r gU i d e
Clearing AllFrame Output Level Settings
The Channel Settings menu contains two commands that can be used to clear AllFrame analog output
level settings. Choose cl e A r ou t p u t ch A N N e l se t t I N g s to reset the selected channel back to its default,
+24dBu. Use the cl e A r Al l ou t p u t ch A N N e l se t t I N g s command to set all analog outputs back to the default
setting.
The Clear Output Channel Settings commands return analog outputs to the default +24dBu setting.
Save AllFrame output levels as part of a Device Preset or Scene to simplify device configuration and setup.
P No t e : The output level reset commands are only available on AllFrame devices.