Invalid Sensors and Error Conditions
Entegra EXP5000 PFD -46- 600-00142-000 Rev 01
4.5 Recoverable Attitude
Figure 16. Recoverable Attitude Situation
If a recoverable attitude data failure occurs:
1) All normal button labels are removed.
2) Attitude data is removed from the display and replaced with a red
X.
3) A Fast Erect button label and message displays.
When you press Fast Erect, the message will change to “Maintain
straight and level flight” until the 10 second count-down timer
expires. At that point, all attitude data is restored.
!
It is imperative that you obtain straight and level flight before
pressing
Fast Erect. Use the backup instruments and/or
outside visual references to obtain straight and level
conditions.