Installation manual
Installation Manual
P/N 600-00175-000 Rev 04 MFD Feature Setup and Checkout
- 55 -
7. Proceed to step N.
N. Calibrate ROLL GAIN
1. Set the tilt table for 10
o
roll right.
2. Use the GAIN controls to set the GAIN POT /2 setting between 21- and 23-.
3. Set the ROLL ANGLE field to 0.0 ±1.0
o
.
◆ To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
◆ To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
◆ When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4. Set the tilt table for 10
o
roll left. Repeat Steps 2 and 3 of this section.
5. Set the tilt table for 0
o
pitch and roll.
6. Proceed to step O.
O. Calibrate ROLL OFFSET
1. Use the GAIN control to set the GAIN POT /2 setting between 14- and 16-.
2. Check that the tilt table is set for 0
o
roll.
3. Set the ROLL ANGLE field to 0.0 ±1.0
o
.
◆ To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
◆ To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
◆ When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4. Set the tilt table to 10
o
roll right. The value should be 10.0R ±1.0
o
. If the value is out of range,
repeat step N.
5. Set the tilt table to 10
o
roll left. The value should be 10.0L ±1.0
o
. If the value is out of range,
repeat step N.
6. Set the tilt table to 0
o
roll. The value should be 0.0 ±1.0
o
. If the value is out of range, repeat
this step (step O.).
7. Proceed to step P.
P. Save Configuration
1. Adjust the GAIN controls for a GAIN POT /2 setting to 4- or 5-.
2. The FAULTS field will display GYRO.