Installation manual

Installation Manual
P/N 600-00175-000 Rev 04 MFD Feature Setup and Checkout
- 55 -
7. Proceed to step N.
N. Calibrate ROLL GAIN
1. Set the tilt table for 10
o
roll right.
2. Use the GAIN controls to set the GAIN POT /2 setting between 21- and 23-.
3. Set the ROLL ANGLE field to 0.0 ±1.0
o
.
To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4. Set the tilt table for 10
o
roll left. Repeat Steps 2 and 3 of this section.
5. Set the tilt table for 0
o
pitch and roll.
6. Proceed to step O.
O. Calibrate ROLL OFFSET
1. Use the GAIN control to set the GAIN POT /2 setting between 14- and 16-.
2. Check that the tilt table is set for 0
o
roll.
3. Set the ROLL ANGLE field to 0.0 ±1.0
o
.
To increment the value of the ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the ROLL ANGLE field will slowly increase.
To decrement the value of ROLL ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the ROLL ANGLE field will slowly decrease.
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4. Set the tilt table to 10
o
roll right. The value should be 10.0R ±1.0
o
. If the value is out of range,
repeat step N.
5. Set the tilt table to 10
o
roll left. The value should be 10.0L ±1.0
o
. If the value is out of range,
repeat step N.
6. Set the tilt table to 0
o
roll. The value should be 0.0 ±1.0
o
. If the value is out of range, repeat
this step (step O.).
7. Proceed to step P.
P. Save Configuration
1. Adjust the GAIN controls for a GAIN POT /2 setting to 4- or 5-.
2. The FAULTS field will display GYRO.