Installation manual

Installation Manual
Radar Sensor Setup P/N 600-00175-000 Rev 04
- 50 -
4. Press Enter to accept the new values.
5. When you are done, press Save from the Radar Setup Page. Press Cancel to exit without saving
changes.
6. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.
Calibrating the AlliedSignal (Bendix/King) 2000/2100 Radar Sensor
This section describes Post-Installation System Configuration and Calibration of the Bendix/King ART-
2000/2100 Radar System using the EX500/EX600 and replaces specific sections of the Bendix/King
Installation Manual that describe configuration and calibration using the Bendix/King IN-182A
Indicator.
To configure and calibrate the system, follow the original Bendix/King Installation Manual substituting
the following two sections with the instructions provided herein:
2.4.1 CONFIGURATION PROCEDURE USING RADAR INDICATOR
2.4.4.1 Stabilization Calibration with Radar Indicator
Note: If the EX500/EX600 is replacing the indicator of a currently installed and previously calibrated
ART-2000/2100 Series Radar, this procedure may not be necessary. The calibration values
are contained in the configuration module of the R/T and should remain valid. Avidyne
recommends that you check the calibration values after the Avidyne unit has been installed to
ensure that nothing has changed.