Installation manual

Installation Manual
P/N 600-00175-000 Rev 04 MFD Feature Setup and Checkout
- 45 -
5.8.2 TAWS Communications Check (Messages)
If there is a communication or data error between the TAWS sensor and the MFD, one of the following
messages will display on the bottom of the screen.
Note: If the EGPWS interface is operating properly, there will be no system status messages.
Table 19: TAWS Error Messages
Message Meaning/Action
TAWS Failed The system configuration is incorrect or one of the system components has failed.
Verify that the sensor is turned on and valid.
Verify system wiring.
TAWS Initializing If message does not clear within 60 seconds, communication between the MFD and the
Terrain sensor has not been established.
Verify that the sensor is turned on and valid.
Verify system wiring.
See terrain sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Not Communicating Indicates that the MFD is not receiving data from the Terrain sensor.
Verify that the sensor is turned on and valid.
Verify system wiring.
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Display Unavailable The TAWS Sensor has declared itself inoperative.
Verify system wiring.
Verify that the sensor inputs to the TAWS are turned on and valid.
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Sensor Self-Test The TAWS Sensor is performing a Self-Test. The message will remain until the self-test
is finished.
Verify that the “Self-Test” mode has been not been selected at the separate TAWS
control panel.
Verify system wiring.
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.
TAWS Inhibited The TAWS sensor is in the “Inhibited” mode.
Verify that the “Inhibit” mode has been not been selected at the separate TAWS
control panel.
See TAWS sensor Installation and User’s Manual for troubleshooting guidance.