Owner`s manual
4
The manufacturer has set the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange
capacity and gallon capacity. The salt dose refill time has been preset.
The dealer should read this page and guide the installer regarding hardness, day override, and time of
regeneration, before installation:
For the installer, the following must be used:
Set Installer Settings… Hardness (preset to 20 gpg), Day Override (preset to 3 days),
and Time of Regeneration (preset to 2 am).
Read Normal Operating Displays
Set Time of Day
Read Power Loss & Error Display
Water Softeners:
During operation, the normal user displays are time of day, gallons per minute or gallons remaining before
regeneration will occur. Days remaining is an optional display but is not normally used on metered softeners.
Each of these can be viewed by pressing NEXT to scroll through them. When stepping through any displays or
programmings, if no buttons are pressed within 5 minutes, the display returns to a normal user display. Any
changes made prior to the 5 minute time out are incorporated.
If desired, two regenerations within 24 hours are possible with a return to the preset program. To do a double
regeneration:
1. Press the REGEN button once, REGEN TODAY will flash on the display.
2. Press and hold the REGEN button for three seconds until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the
preset time.
The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in
order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions
including a diagnostic position that allows a service technician to have pressure to test a system while providing
untreated bypass water to the building.
Be sure to install bypass valve onto main control valve, before beginning plumbing or make provisions in the
plumbing system for a bypass.
The bypass body and rotors are glass filled Noryl
©
and the nuts and caps are glass filled polypropylene. All
seals are self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings
can easily be replaced if service is required.
The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped
handles. The handles identify the direction of flow. The plug valves enable the bypass valve to operate in four
positions.
Preinstallation Instructions Cont.
BYPASS VALVE: