Owner`s manual

10
2. Programming cont’d:
STEP 4 -- Regeneration Hour: The manufacturer has factory set 2:00 am as the default. This is the
hour of day for regeneration and can be reset by using or buttons. “AM/PM” toggles
after 12. The default time is 2:00 a.m. (recommended for a normal household). Press next
to go to step 5. Press regen if you need to return to the previous step.
STEP 5 -- Regeneration Minutes: Set the minutes using or buttons. Press next to exit Installer
Settings. Press regen if you need to return to the previous step. To initiate a manual
regeneration immediately, press and hold the regen button for three seconds. The system
will begin to regenerate immediately. The control may be manually stepped through the
regeneration cycles by pressing regen.