Setup guide

Starting and Stopping the Test
41
Starting and Stopping the Test
You start and stop the currently configured test using the Start and Stop
buttons.
To start the currently configured test:
t Click Start in the Avid Performance Meter main window.
The test runs for the specified duration and then stops automatically.
The elapsed time a test has been running and the remaining time are
displayed in the Control area. If you selected the Loop option in the
Avid Performance Meter Settings dialog box, the test runs indefinitely.
In this case, the word LOOP appears in the Time Remaining display in
the main window.
To stop the currently running test:
t Click Stop in the Avid Performance Meter main window.
Interpreting the Test Results
This section provides information to help you interpret test results
displayed in the Avid Performance Meter main window.
Average Rate Calculation
The average data rate is calculated over the duration of the test. This
calculation includes the time the utility requires to open and to close the
test files, so the test file size (which you can configure for custom tests) can
affect the overall measured throughput.
Also, if the throughput is slow as the test is starting, this might be reflected
in the average rate. For example, if the target bandwidth is 4.0 MB/s, the
actual average rate calculated at the conclusion of the test might be 3.98 or
3.99 MB/s.