Setup guide
Appendix A Avid Performance Meter
36
Setting Up a Standard Test
To change the default test settings:
1. Click the Setup button.
The Avid Performance Meter Settings dialog box opens.
2. Adjust the test parameters described in the following table, as required:
Parameter Description
Test Name Select one of the following standard, predefined tests:
• DV 25 Reads
• DV 25 Writes
• DV 50 Reads
• DV 50 Writes
These selections perform either read or write testing at a
bandwidth similar to that required for DV 25 or DV 50 operation.
Path to Test Select the path to the workspace you want to test, or type it in the
text box.
This can be a UNC path (for example, \\myMachine\
myShareFolder\subfolder). If you selected the Unity Path option,
use a MediaNetwork path supported by LANserver.
Unity Path Select the Unity Path option to have Avid Performance Meter
convert the specified MediaNetwork path to a standard path.