User guide

Table Of Contents
Chapter 5: CM402T Expanded Channel Module 59
Knobset Control Panel
The Knobset Control Panel configures the knobs above the panel and which pages of Dynamics and EQ appear below it. The
Input and Aux functions have configuration pages which can be accessed by pressing both cfg  keys simultaneously (see
“Channel Functions” on page 77 for details about configuration pages). The LCD in the center of the panel shows the current Cen-
ter Strip channel.
The Knob Values key toggles the knob’s LCD between the parameter name (unlit) and the parameter value (lit). The LCD always
displays the value when the knob is adjusted, but reverts to the name unless Knob Values is lit.
The five Preset keys (P1–P5) configure the two panels of eight knobs above the Knobset Control Panel. The current preset key re-
mains lit and the top two (right and left) LCDs show the selected functions. The bottom two LCDs are fixed at Dynamics and EQ.
The Select switch punches in the knobset during automation, or selects it for inclusion in a Snapshot. The In key switches the func-
tion In (lit) and Out (unlit). The switch to the right of the In key is the Select/Punch for the In key.
All knobset functions and displays are discussed in “Channel Functions” on page 77.
Knobset Control Panel
Center Panel Knobset Presets
Preset # Left Right
1 Aux Filters
2 Aux Input
3 Input Filters
4AuxAux
5 Input Input
The Store P and Assign Knobs switches are not currently operational.
EQ
12:GuitAux
Dyn
in
in
in
P1 P2 P3 P4 P5 Store P
KnobValues
Assign Knobs
Select
Select
in
cfgcfg
Filt