Chapter 3: eMix Application 17
Title Defaults
This section describes how to set up basic PatchNet settings when a new Mixer Model is selected. This process includes naming
the sources and destinations and connecting group bus outputs to multitrack inputs. The setup process is equivalent to setting
and labeling the normalled connections on a conventional patch.
These settings are stored to the Title Defaults and are automatically included with each new Title. Each Mixer Model has a Title
Defaults file.
A new Title inherits these settings from the Title Defaults:
• PatchNet names and settings
• Bus names and formats
• Externals names and formats
• SnapShots
•Layouts
• Meter setups
.
Setting the Title Defaults
The Title Defaults can be set by clicking the Set Title Defaults button on the Titles page in PatchNet. This copies all settings listed
above from the currently open Title into the Title Defaults for the current Mixer Model. The figure below warns about this action.
A destination refers to an external device input, not the console.
The Title Defaults is a file on the System Computer for each Mixer Model, but it does not appear in the Directory.
Updating Title Defaults warning