System 5 Digital Audio Mixing System User Guide158
Deleting Events
Delete an event by selecting the event, input, or output and pressing the Delete Selected Entry button at the bottom left of the
Events screen.
GPI Examples
Refer to the two previous figures for these examples. The options available in the Input and Output Properties areas are summa-
rized in tables on page 154 and page 155.
Using a Fader to Turn Devices On and Off
To turn off the floor monitors by moving any one of several faders above a selected level:
1 In the Event Configuration window, under Event List, click the <click to add event> field.
The Add Event dialog appears.
2 Select Or as the logical operator from the menu.
3 Under Input, click the <click to add input> field.
The Add Input Event dialog appears.
4 Select Fader from the menu and click OK.
5 Configure the Input Properties to the following settings:
6 Repeat steps 3–5 for additional channel faders, but set the Channel # in step 5 to the new channel number.
7 Under Output, click on the <click to add output> field.
The Add Output Event dialog appears.
8 Select Control Room from the menu and click OK.
9 Configure the Output Properties to the following settings:
To turn on the floor monitors by moving any one of several faders below a selected level:
1 In the Event Configuration window, under Event List, click on the <click to add event> field.
The Add Event dialog appears.
2 Select OR as the logical operator from the menu.
3 Under Input, click on the <click to add input> field.
The Add Input Event dialog appears.
4 Select Fader from the menu and click OK.
An event with just one input delivers the same result with AND and OR, so they may be used interchangeably.
Channel # 1
Activation level (dB) -50
Activation Type Above
Action Monitor A
Active State Off