Specifications

Chapter 2: Software Configuration 7
Resolving Unexpected Modules
To resolve any modules that appear as Unexpected during startup:
1 Control-click each Unexpected module until all are selected.
2 Click Save selected as default, and confirm the selection by clicking OK.
3 Click Continue to finish booting eMix.
4 Power up the workstation computer running Pro Tools.
5 Power up the workstations running other DAWs (if any).
6 Follow the instructions in “Enabling EUCON in Pro Tools” on page 7.
Enabling EUCON in Pro Tools
To enable EUCON control in Pro Tools:
1 Make sure MC Client and EUCON Discovery software are running.
2 Launch Pro Tools.
3 Choose Setup > Peripherals, and click the Ethernet Controllers tab.
4 Select Enable EUCON.
When eMix launches, the control surface is temporarily disabled and audio is muted. Launching eMix
automatically by putting it in the Windows Startup folder may produce undesirable behavior if the
System Computer reboots during a broadcast or session.
On Hybrid systems’ SC264, confirm that EUCON Discovery is set to use the second LAN connection
and that it is not on the System 5 connection.
Enabling EUCON in the Peripherals dialog