Specifications

S3L System Guide150
Channel Control Dynamics Parameter
Mapping
The following tables show how Dynamics parameters are
mapped to the Channel Control encoders and their corresponding
In and Sel switches.
Comp/Lim Parameter Mapping
Exp/Gate Parameter Mapping
Control Ranges for Built-In Dynamics
Comp/Lim Defaults and Ranges
Exp/Gate Defaults and Ranges
Channel Control Comp/Lim parameter mapping
Channel
Control
Encoder
Encoder
Rotate
Encoder Sel
Switch
Encoder IN
Switch
1 Threshold level n/a Comp/Lim
in/out
2 Ratio n/a n/a
3 Attack n/a n/a
4 Knee n/a n/a
5 Release n/a n/a
6 Gain level n/a n/a
7 Key HF Key Listen Filter in/out
8 Key LF Key In Filter in/out
Channel Control encoder Exp/Gate parameter mapping
Channel
Control
Encoder
Encoder
Rotate
Encoder Sel
Switch
Encoder IN
Switch
1
Threshold level n/a Comp/Lim
in/out
2
Ratio n/a n/a
3
Attack n/a n/a
4
Knee n/a n/a
5
Release n/a n/a
6
Gain level n/a n/a
7
Key HF Key Listen Filter in/out
8
Key LF Key In Filter in/out
Comp/Lim (defaults to Compressor mode)
Parameter Default Minimum Maximum
Threshold 0 dB –40 dB +20 dB
Attack 10 ms 100 us 200 ms
Release 100 ms 10 ms 4 sec
Ratio 2:1 1.25:1 100:1
Knee 0 (hard) 0 100
Makeup Gain 0 dB –40 dB +20 dB
Exp/Gate Defaults (defaults to Gate mode)
Parameter Default Minimum Maximum
Threshold 0 dB –60 dB +20 dB
Attack 1 ms 20 us 500 ms
Release 250 ms 10 ms 4 sec
Ratio
100:1 (Gate
mode)
1.25:1 100:1
Gate Hold 100 ms 10 ms 4 sec
Gate Range –20 dB –80 dB 0 dB