DF66 Guide System 5
Legal Notices This guide is copyrighted ©2011 by Avid Technology, Inc., (hereafter “Avid”), with all rights reserved. Under copyright laws, this guide may not be duplicated in whole or in part without the written consent of Avid.
Contents Chapter 1. Introduction to the DF66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 System Requirements and Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 About This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv DF66 Guide
Chapter 1: Introduction to the DF66 The DF66 is an audio DSP core for the System 5 and MaxAir console families. The DF66 contains four types of cards: SP663 DSP Line, Bridge (five types), Sync, and SNMP. Features of the DF66 include: • 4U rack-mountable chassis • Up to six 120MHz DSP cards About This Guide This guide provides a basic overview of DF66 features and functionality. For complete instructions on connecting and configuring your system, see the System 5 Installation Guide.
About www.avid.com The Avid website (www.avid.com) is your best online source for information to help you get the most out of your system. The following are just a few of the services and features available. Product Registration Register your purchase online.
Front Panel DF66 Front Panel Front Panel Elements Status Module Power Switch and Status Indicators See Status Module below. Software Status Indicator The blue wave icon in the Euphonix logo lights up to indicate the software in the DF66 is operating correctly. Detail of Status Module on Front Panel System Reset Switch Forces a manual reset of the FD66. Alarm Cancel Switch Cancels the audible hardware fault alarm. USB Ports Connect a USB storage device to update software.
Back Panel Locked LED Indicates that the DF66 is receiving from and locked to the selected sync source. This LED must be lit for proper DF66 audio operation. VGA (DB-15), Keyboard (PS2), Mouse (PS2) Used for configuration and service connections only. LAN Port 1 (RJ45) Connect to EUCON Network Switch via RJ45 (provided). LAN Port 2 (RJ45) Not used. Power Connectors (IEC) Accepts two standard IEC power cords (provided).
Sync Card SP663 DSP Line Card AES In (3-pin LEMO Female or BNC) The DF66 clocks to the signal at this port when the sync source is set to AES Sync. Connect this port to a digital sync reference. The SP663 has four MADI In and four MADI Out on a Combination D (Combo D) Subminiature connector. A MADI I/O DSP Line Card Cable connects the Combo D connector to the eight BNC connectors. Word In (BNC) The DF66 clocks to the signal at this port when the sync source is set to Word Clock.
6 DF66 Guide
Chapter 2: Installation MADI I/O MADI I/O MADI I/O MADI I/O MADI I/O MADI I/O Card 2 Card 3 Card 4 Card 5 Card 6 SYNC Card 1 Connections Lock 75 AES In 110 AES In 75 Word In 75 Sync Network Word Out DF66 Back Panel (detail) Network Connect the left Ethernet port (from the rear) to the console’s Ethernet switch. Sync Connect a digital reference signal from a master clock source to one of the sync inputs. Be sure to select this as the sync source when configuring the DF66.
Failover System The Boot and Diagnostic screens show two DSP Cores as DSP Core 1 and DSP Core 1A. The DSP core ID settings configure the designation. (See “General Settings” on page 9.) DSP Core 1 boots as the active core, DSP Core 1A is redundant. If DSP core 1A is not detected during boot, the failover option will be disabled (grayed out) in the GUI. The Failover switch (SH612) is controlled by the SC262 System Computer via a RS232-to-RS422 converter.
Chapter 3: Configuring the DF66 DF66 configuration settings can be changed from the System PC with a Web browser. General Settings To access DF66 configuration settings: 1 With the system running, choose Start > Programs > Internet Explorer. 2 Type the address http://192.168.0.200/cgi-bin/config.cgi and press Enter. 192.168.0.200 is the default IP address for the DF66. General Settings window Name Enter a name for the system. ID Default value is 1.
System PC Configuration 1 Open the Computer Management applet by choosing Start > Settings > Control Panel > Administrative Tools > Computer Management. Network Settings The Network Settings configuration has not yet been implemented. You can set the IP address manually by editing the d:\dsppilotapp.ini file on the DF66. 2 In the left pane, expand Local Users And Groups, and select Users.
Updating Software SP663 DSP Card Firmware Before updating software, start up the system with the existing version of software. To check the firmware version of the DSP cards: 1 On the eMix diagnostics page, select Pilot 1. To update eMix software: 2 Scroll down the page to make sure all cards say Firmware Re- 1 Copy setup.exe to the System PC. vision 16. (This may take a few attempts because the page jumps to the top every few seconds when it refreshes.
12 DF66 Guide
Appendix A: DF66 Specifications DF66 Specifications Synchronization Sync Inputs AES, Word AES In: 1 Lemo 3-pin (110 AES In: 1 BNC (75 Word In: 1 BNC (75 Sync Outputs Word Out:1 BNC (75 Internal: 44.1, 48, 96 kHz +/-20ppm Sample Rate Sample Rate Range (Fs) Locking to External Source: 40 kHz - 48.48 kHz (1fs mode) 80 kHz - 96.
DF66 Environmental Specifications Humidity 0-90% non-condensing Operating Temperature 0–35C Storage Temperature -10–55C DF66 Dimensions 14 DF66 Guide Height 7 in (177 mm) Width 19 in (482 mm) Depth 19 in (482 mm) Weight 44 lb (20 kg)
Appendix B: Compliance Information Environmental Compliance Disposal of Waste Equipment by Users in the European Union Proposition 65 Warning This product contains chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. Perchlorate Notice This product may contain a lithium coin battery.
EMC (Electromagnetic Compliance) Avid declares that this product complies with the following standards regulating emissions and immunity: • FCC Part 15 Class A • EN55103-1 E4 • EN55103-2 E4 • AS/NZS CISPR 22 Class A • CISPR 22 Class A FCC Compliance for United States Communication Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Safety Compliance Safety Statement This equipment has been tested to comply with USA and Canadian safety certification in accordance with the specifications of UL Standards: UL 60950-1:2007, 2nd Ed and CAN/CSA-22.2 No. 60950-1-07, 2nd Ed. Avid Inc., has been authorized to apply the appropriate NRTL mark on its compliant equipment. Warning 13) Unplug this equipment during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel.
18 DF66 Guide
Avid Technical Support (USA) Product Information 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA Visit the Online Support Center at www.avid.com/support For company and product information, visit us on the web at www.avid.