Specifications

Appendix B: DigiTest Error Codes 87
appendix b
DigiTest Error Codes
DigiTest Error Codes
Code Description
Err3 Cards from different Pro Tools
systems are incorrectly mixed.
Err4 Cards marked with this error are
installed in the wrong order.
Err5 Too many cards of this type are
installed in the system. Refer to
the Digidesign Web site for com-
patibility information:
www.digidesign.com/compato/
Err6 A card is installed in a reserve
slot. For example, a Digidesign
card is installed in the slot
reserved for the Expansion Chas-
sis Host Interface card.
Err1010 Too many MIX Core cards
installed. The maximum number
of MIX Core cards allowed is 7.
Err1011 Too many MIX Farm cards
installed. The maximum number
of MIX Farm cards allowed is 7.
Err1012 Too many total MIX cards
installed. The maximum number
of total MIX cards allowed is 7.
Err1020 Too many d24 Core cards
installed. The maximum number
of d24 Core cards allowed is 2.
Err1021 Too many MIX I/O cards installed.
The maximum number of MIX I/O
cards allowed is 2.
Err1022 Too many total d24 cards
installed. The maximum number
of total d24 cards allowed is 2.
Err1220 SCSI Accelerator card is installed
in the wrong slot.
Err1221 Expansion Chassis Host Interface
card is installed in the wrong slot.
Err1301 A Core card is not installed. At
least one Cord card is needed.
Err1310 A DSP Farm card is not installed.
At least one DSP Farm card is
needed.
DigiTest Error Codes