User`s guide

Chapter 2: Installation and Setup
Pinnacle Systems DekoMOS User’s Guide 33
To configure connections:
1. Access the DekoMOS Gateway Configuration window if it is not already open. Select the
Connections tab.
2. In the Primary NCS area, enter these settings:
In the Address field, enter the IP address for the iNews Gateway or ENPS server
For the Lower Port, Pinnacle Systems recommends keeping the default setting of 10540 unless
you receive an error message.
For the Upper Port, Pinnacle Systems recommends keeping the default setting of 10541 unless you
receive an error message.
3. Enable or disable Automatic Fail-over by clicking the checkbox. If the Gateway loses
connection to the NCS, the Gateway will automatically try to reconnect. If it cannot
reconnect, and Automatic Fail-over is enabled, the Gateway will try to connect to the fail-over
NCS. If the Gateway cannot connect to the fail-over NCS, it will continue to alternate
connection attempts to the NCS and the fail-over NCS until it connects to one. If you enable
Automatic Fail-over, enter information in the Fail-over NCS area:
In the Address field, enter the IP address for the fail-over iNews Gateway or ENPS server
For the Lower Port, enter 10540.
For the Upper Port, enter 10541
4. In the MOS ID area, enter settings as follows:
In the Gateway ID field, enter the name that you have decided upon and defined in the NCS. This
unique MOS ID string identifies the DekoMOS Gateway and is defined in the ENPS or iNEWS
server configuration.
In the NCS ID field, enter the NCS ID assigned by your system administrator.
Reject items with incorrect Gateway ID should be checked unless you are using DekoMOS with an
ENPS system and MOS Redirection.
5. In the Listening Ports area:
Client Port default setting is 10542. Pinnacle Systems recommends keeping this setting.