8 Log out of all your workstations and log back in. Note the following:
• You may need a separate keyboard and mouse to do this since EUCON connectivity will not be established at this point.
• When you log out, all EUCON-based processes are shut down and relaunched again when you log in. This ensures that the
new custom network settings are applied to the workstation.
• Alternatively, you may restart your workstations, although it should not be necessary.
9 Re-attach all your workstations and CM408T modules.
To set the system back to default multicasting settings:
1 Connect to all the workstations and modules whose settings you want to change.
2 Only workstations assigned to the four workstation switches will be affected by this change. Only CM408T modules “Assigned
to this MC” will be affected by this change.
3 Go to Euphonix menu > Prefs > Network tab.
4 Deselect the Use Custom Settings button.
The default factory multicast settings should now appear in the fields below in DIM lettering.
5 Go to the Setup > Modules page on the MC and “remove” all the attached CM408T modules.
6 Restart all CM408T modules by pressing the RESET button located on the bottom front of the units.
7 Restart the MC.
8 Go to Euphonix Menu > Shutdown.
9 Press Restart.
10 Log out of all your workstations and log back in. Note the following:
• You may need a separate keyboard and mouse to do this since EUCON connectivity will not be established at this point.
• When you log out, all EUCON-based processes are shutdown and relaunched again when you log in. This ensures that the
network settings are applied to the workstation.
• Alternatively, you may restart your workstations, although it should not be necessary.
11 Re-attach all your workstations and CM408T modules.
Base: 224.1.239.0
Mask: 255.255.255.0
Discovery: 224.1.239.2 Port: 4242
EuCon 224.1.239.42 Port: 4245
Logging: 224.1.239.3 Port: 4243