User guide
Appendix A: Studio Monitor Pro 2 109
Parameters
Control Room
The Control Room O/P feed provides additional features:
Speaker Selection
• Main: up to 7.1 multi-channel O/P
• Alt 1 and Alt 2: provided for additional stereo speaker O/P’s.
Fixed
This sets the level of the CR to the specified fixed level set in the Configuration tab.
Reverse
Reverses polarity (180º phase) of the Left O/P signal.
Monitor Insert Send / Return
(Control Room Feed Only)
The Monitor Insert Send and Return switches turn on/off the Insert signal paths.
Insert Send Patching is assigned in the SMP O/P section.
Insert Return Patching is assigned in either the Hardware I/P or Application O/P sections.
• Return Format: The Insert Return Format selector allows for the User Format channel assignments to be applied to the in-
coming Insert signal.
Comms: Talkback
Used to engage any of the four Talkbacks. Talkback 1 is accessible from the MC surface Control Room section.
A/B Matrix Switching
SMP2 allows for two separate SMP I/P patch configurations: A/B. The A-B Matrix buttons are used to select either SMP I/P A or B
configuration.