Product specifications

Avid ISIS System Director Control Panel
58
Metadata memory is also saved automatically to the Partition0 and Partition1 files when the System Director stops
normally and without error. A third file, PartitionDump.bin, containing an alternate representation of the file system
metadata is also created. The PartitionDump.bin file should be used only when adding memory to a System director
or moving to a newer System Director with more memory, unless otherwise instructed by Avid Customer Support.
The Metadata Status box shows when the metadata was last verified and saved, and replicated. A green indicator
means no problem has been detected. A yellow indicator means the status is uncertain. A red indicator means that a
problem exists.
The following tables lists the status messages displayed in the Metadata Status box.
Creating a Metadata Dump File
You can use the “Dump Metadata” function to write all metadata information to a text file.
n
This operation should be used only as a diagnostic aid. You cannot restore ISIS metadata from a metadata dump file.
c
When you write metadata to a file, the resulting file is extremely large and takes a long time to create. Do not
use this option unless instructed to do so by Avid Customer Support.
To write the contents of metadata to a text file in the System Director directory:
t In the System Director toolbar, click Dump Metadata.
A text file called PartitionDump.txt is created in the System Director’s data directory:
Status Category Messages Additional Notes
Overall Status Metadata loaded
Validating
No Metadata loaded
Loading nn.n MBps
State Unknown
System Director is running
Occurs periodically
System Director is stopped or metadata is unable to
load for some reason
System Director is restarting
Verification •Not Active
Verified
Verify Failed
State Unknown
When the System Director is in standby mode, the
Verify indicator is disabled.
Saving •Saving
•Saved
Unknown State
•Not Active
Save Failed
Replication Sending
Receiving
Unknown State
•Not Active
Replication Failed
When the System Director is not in a Dual System
Director configuration, the Replicate indicator is
disabled.