The following table provides information on operating and storage temperature, and humidity specifications for
the Avid hardware components. Make sure your environment meets the narrowest range of specifications in the
table.
For example, the System Director can operate in an environment of 32°F to 122°F (0°C to 50°C), but the ISIS
Engine should only operate in an environment of 40°F to 95°F (5°C to 35°C). Therefore, the temperature at your
site should not drop below 40°F (0°C) or rise above 95°F (35°C) while the Engine is running.
Switch Environmental Specifications
Switch
Operating
Temperature
Operating
Humidity
Storage
Temperature
Storage
Humidity
Arista Networks 7048T 32° F to 104° F
(0°C to 40°C)
5% to 95%
relative humidity
– 40° F to 158° F
(– 40°C to 70°C)
5% to 95%
relative humidity
Cisco Catalyst 4948E,
4948-10GE, and 4900M
32°F to 104°F (0°C
to 40°C)
10% to 90%
non-condensing
– 40° F to 167° F (–
40°C to 75°C)
0% to 95%
non-condensing
Cisco Catalyst 4500-X 32°F to 104°F (0°C
to 40°C)
10% to 90%
non-condensing
– 40° F to 158° F (–
40°C to 70°C)
95% relative
humidity
Cisco Catalyst 6500-E series 32°F to 104°F (0°C
to 40°C)
5% to 90%
non-condensing
– 4° F to 149° F
(– 20°C to 65°C)
5% to 95%
non-condensing
Cisco Nexus 7000 series 32°F to 104°F (0°C
to 40°C)
5% to 90%
non-condensing
– 40° F to 158° F (–
40°C to 70°C)
5% to 95%
non-condensing
Dell Networking
N3024, N3048
32° F to 113° F
(0°C to 45°C)
95% – 40° F to 149° F
(– 40°C to 65°C)
85%
non-condensing
Dell Networking
S25N, S25P, and S60
32° F to 122° F
(0°C to 50°C)
10% to 85% – 40° F to 158° F
(– 40°C to 70°C)
5% to 95%
non-condensing
Dell Networking
S4810
32° F to 104° F
(0°C to 40°C)
10% to 85%
non-condensing
– 40° F to 158° F
(– 40°C to 70°C)
5% to 95%
non-condensing
Foundry
FESX424 and FESX624
32°F to 104°F (0°C
to 40°C)
5% to 90%
non-condensing
– 13°F to 158°F
(–25°C to 70°C)
5% to 90%
non-condensing