Specifications

192 Digital I/O Guide14
Digital Format Settings and
Sample Rate Conversion
To configure digital formats and sample rate
conversion:
1 Click on the Digital tab and select Input For-
mat (AES/EBU, ADAT, or TDIF).
2 Enable real-time Sample Rate Conversion by
selecting channel pairs (1–2, 3–4, 5–6, 7–8) in
the SR Conversion box on the Digital tab.
To configure additional interfaces:
Repeat the above steps for additional HD-se-
ries I/O in the Peripherals list. To configure the
Main tab of a secondary HD peripheral attached
to a primary HD I/O, you must first choose the
I/O in the Peripherals list.
The following example shows how to configure an
HD system with one 192 Digital I/O and one
96 I/O in the Hardware Setup dialog:
1 From the Peripherals list, choose the
192 Digital I/O (which must be your primary
I/O for any sample rates higher than 96 kHz). By
default, the Main tab will be selected, and op-
tions and controls for the selected I/O will be
available. The expansion interface connected to
the primary I/O will appear below it in the Pe-
ripherals column.
2 In the Main page, ensure that Expansion I/O is
selected under Port Settings.This is the default.
3 From the Peripherals list, select your second-
ary I/O (in this case, the 96 I/O).
4 Configure the Main page and other settings
and options for the secondary peripheral.
Legacy I/O Setup
For details about Legacy I/O Setup, please con-
sult the Getting Started with HD Guide.
At session sample rates above 48 kHz, sam-
ple rate conversion for the TDIF and Optical
(ADAT) inputs on the Digital I/O card is
automatically enabled on all eight inputs of
the selected format.
Hardware Setup dialog with Digital tab selected