Specifications

192 I/O Guide18
Analog Input Settings
To configure analog input options:
Click on the Analog In tab and select the Ref-
erence Input Level (+4 dBu or –10 dBV, which
also determines which port is used on the rear of
the 192 I/O), Input Trim settings (A or B), and
Soft Clip limiter function, respectively, on each
channel. See “Setting Operating Levels” on
page 21 and “Soft Clip Limiting” on page 23.
Refer to “192 I/O Back Panel” on page 5 to lo-
cate the different ports and connectors de-
scribed in this section.
Analog Output Settings
To configure analog output options:
Click on the Analog Out tab and select which
trim setting will be used for the individual ana-
log outputs. The default is A and comes from the
factory set for a headroom value of 18 dB. The
B trim comes from the factory with 20 dB of
headroom. See “Setting Operating Levels” on
page 21.
Hardware Setup dialog with Analog In tab selected
Hardware Setup dialog with Analog Out tab selected
While there are two discrete sets of inputs at
the reference levels of –10 dBV and +4 dBu,
there is only one set of outputs, set at a refer-
ence level of +4 dBu.