Specifications

FT730 Guide4
Back Panel
1. Power Connectors (IEC)
Accepts two standard IEC power cords (provided). Two au-
toranging switching supplies accept voltages in the range
100–240 VAC, 50–60 Hz.
1. AES/SYNC IN (female XLR or BNC), WORD IN (BNC)
Connect this port to a digital sync reference (local unit only).
Selection for XLR or BNC input is done using two internal
jumpers shown in Figure 4. The unit is shipped with the jump-
ers set for the XLR input.
2. AES/SYNC OUT (male XLR or BNC), WORD OUT (BNC)
Connect one of these ports to the digital sync reference input
of any device receiving MADI at the remote unit. Only one
output connection (XLR or BNC) should be used at a time.
3. RETIMED AES/SYNC OUT (male XLR), RETIMED WORD
OUT (BNC)
Connect one of these ports to the digital sync reference input
of any device sending MADI from the remote unit back to the
local unit. See Synchronization for Distances Over 800 ft (250
m) on page 13 for more information about these outputs.
FT730 back panel
I
O
I
O
1
1
FT730 back panel (detail)
123