2 Connecting the ISIS Equipment
26
Securing the Outer Slide Rail to the Rack-Mounting Rail
5. Adjust the outer slide rail bracket assembly to the rear mounting rail.
6. Secure the rear outer slide rail bracket assembly to the rear mounting rail as you did for
the front rack-mounting rail.
7. Repeat this procedure to attach the second outer slide rail on the other side of the rack.
Securing the File Gateway Server in a Rack
c
Have someone help you lift the File Gateway server while you are positioning it into the
slide rails.
To secure the server to the rack enclosure:
1. Lift and position the server so that the inner slide rails (secured to the File Gateway
server) are aligned with the outer slide rails secured to the rack.
2. Push the front of the File Gateway server flush against the front mounting rail. The holes
in the server front panel align with the holes in the front mounting rail.
3. From the front of the rack enclosure, insert the large Phillips-head screw through the
File Gateway server and front mounting rail.
- Square hole racks — Use the middle hole of the outer rail kit to secure the server
front panel to the vertical rail. An M6x10 screw is included in the parts kit to secure
the front panel.
- Round hole racks — Attach the server front panel to the vertical rail of the rack. Use
a truss head screw or hardware that comes with your rack to secure the front panel.