Setup guide
Replacing System Drives in the AS3000
39
Intel Rapid Storage Technology Application
A. Run hardware scan button
B. Disk icons
C. Status line
3. Pull the failed drive out of the server and install a replacement without turning off the server.
See “Removing and Installing a Hot-swap Hard Drive” on page 41.
Once the drive is installed, use the Intel Rapid Storage Technology application to initiate the
rebuild operation as described in the following steps.
4. Click the Run hardware scan button (identified as A in the above illustration) to refresh the
RAID data to the current state.
5. The volume icon has two smaller disk icons attached to it - one for each disk of the RAID
set. Perform one of the following operations:
- If the disk has previously been part of the RAID set, the disk appears as an icon attached
to the Volume 0 icon and the application will immediately begin the rebuild. You can
monitor in the status line. In this case the status line will display "Rebuilding x%
complete”.
- If the replacement disk has never been part of this RAID set, the disk icons display a list
of available disks. The Status line will display "Degraded", and the words "rebuild to
another disk" will be underlined. Click on the underlined text.
AA
B
B
CC