Product specifications

Installing the Failover Hardware Components
21
Failover Cluster Connections: Avid ISIS, Redundant-Switch
Configuration
Make the following cable connections to add a failover cluster to an Avid ISIS environment,
using the redundant-switch configuration:
First cluster node:
- Top-right network interface connector (2) to layer-3 switch 1 (VLAN 30)
- Bottom-left network interface connector (3) to the bottom-left network interface
connector on the second cluster node (private network for heartbeat)
- Fibre Channel connector on the ATTO Celerity FC-81EN card to Fibre Channel
connector Port 1 (top left) on the Infortrend RAID array or the HP MSA RAID array.
Second cluster node:
- Top-right network interface connector (2) to layer-3 switch 2 (VLAN 30)
- Bottom-left network interface connector (3) to the bottom-left network interface
connector on the second cluster node (private network for heartbeat)
- Fibre Channel connector on the ATTO Celerity FC-81EN card to the Fibre Channel
connector Port 2 (bottom, second from left) on the Infortrend RAID array or the HP
MSA RAID array.
The following illustrations show these connections.